IIR document
Energy impact of the Internal Heat Exchanger in a horizontal freezing cabinet. Experimental evaluation with the R404A low-GWP alternatives R454C, R455A, R468A, R290 and R1270.
Author(s) : CABELLO R., SÁNCHEZ D., LLOPIS R., ANDREU-NACHER A., CALLEJA-ANTA D.
Type of article: IJR article
Summary
This work analyses the influence of the Internal Heat Exchan ger (IHX) on the energy performance of a vapor compression cycle associated with a freezing cabinet using different R404A low-GWP alternatives. Among them, the refrigerants R454C (GPW100=146), R455A (GPW100=146), R468A (GPW100=146), R290 (GPW100=5) and R1270 (GPW100=1.8) have been tested in a horizontal freezing cabinet maintaining a product target temperature of -20°C at the heat rejection temperatures of 20, 30 and 40°C. The results from tests show that the use of the IHX reduces energy consumption in all scenarios without significantly increasing the compressor's discharge temperature. For a test period of 16 h, the refrigerants that offer better reductions are R404A and R1270, followed by R455A, R290, R454C and R468A. The maximum energy saving is rated to 9.2% at the heat rejection temperature of 40°C, demonstrating that the enhancement of the IHX is better as higher the heat rejection conditions are.
Available documents
Format PDF
Pages: 22-33
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Energy impact of the Internal Heat Exchanger in a horizontal freezing cabinet. Experimental evaluation with the R404A low-GWP alternatives R454C, R455A, R468A, R290 and R1270.
- Record ID : 30029485
- Languages: English
- Subject: HFCs alternatives
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 137
- Publication date: 2022/05
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2022.02.007
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (23)
See the source
Indexing
-
Themes:
HFCs;
Hydrocarbons;
Thermodynamic measurements;
Supermarkets, display cabinets - Keywords: R404A; Substitute; R454C; R455A; R468A; R290; R1270; Thermodynamic property; Expérimentation; Cabinet
-
R-454C, R-459B, R-457A and R-455A as low-GWP re...
- Author(s) : LLOPIS R., CALLEJA-ANTA D., SÁNCHEZ D., et al.
- Date : 2019/10
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 106
- Formats : PDF
View record
-
Nuovi refrigeranti a basso GWP alternativi al R...
- Author(s) : MINOR B., GERSTEL J.
- Date : 2013
- Languages : Italian
- Source: Industria & Formazione - vol. 37 - n. 374
- Formats : PDF
View record
-
Propane as R22-replacement in commercial applia...
- Author(s) : JÜRGENSEN H.
- Date : 2008/11/13
- Languages : English
- Source: Danfoss Compress. - 4 p.; fig.; tabl.
View record
-
Experimental and numerical characterization of ...
- Author(s) : CHAOMUANG N., FLICK D., DENIS A., LAGUERRE O.
- Date : 2020/03
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 111
- Formats : PDF
View record
-
Predicción del histórico tiempo-temperatura en ...
- Author(s) : HOKE K., PRUCHOVA J., KYHOS K., et al.
- Date : 2009/08
- Languages : Spanish
- Source: Frío Calor Aire acondicionado - vol. 37 - n. 416
- Formats : PDF
View record