Energy influence of the IHX with R22 drop-in and long-term substitutes in refrigeration plants.
Author(s) : CABELLO R., TORRELLA E., LLOPIS R., et al.
Type of article: Article
Summary
This work focuses on the investigation of new drop-in or long-term refrigerants for low evaporating temperatures that can be used as substitutes for HCFC-22, which is gradually being phased-out. This process is already in progress in European countries (Regulation CE-1005/2009) and has been accelerated in Article 5 Countries of the Montreal Protocol. Specifically, in this work the energy influence of the suction line/liquid line heat exchanger on the new substitute fluids is addressed from an experimental approach. The study has been based on experimental measurements in a single-stage vapour compression refrigeration plant, which has been tested in the same external conditions operating with and without an Internal Heat Exchanger (IHX). The energy influence of the IHX working with R22 and three potential substitutes for low temperature applications, the chlorine-free drop-in fluids R417B and R422A and the chlorine-free long-term substitute R404A has been analysed. From the experimental results, reductions in capacity and COP have been observed when R22 is replaced by the drop-in fluids, although the presence of an IHX can help to lessen these reductions. Furthermore, the criteria that are usually employed to determine the energy advantage or disadvantage of the use of the IHX with the new refrigerants have been tested, the results confirming that they remain valid for them.
Details
- Original title: Energy influence of the IHX with R22 drop-in and long-term substitutes in refrigeration plants.
- Record ID : 30006031
- Languages: English
- Source: Applied Thermal Engineering - vol. 50 - n. 1
- Publication date: 2013/01
- DOI: http://dx.doi.org/10.1016/j.applthermaleng.2012.06.008
Links
See other articles in this issue (64)
See the source
Indexing
-
Themes:
HCFCs;
Evaporators, condensers and other heat exchangers;
HFCs - Keywords: R422a; Drop-in; R404A; R22; Substitute; Expérimentation; Energy efficiency; Heat exchanger
-
HCFC-22 replacement with HFC drop-in refrigeran...
- Author(s) : LLOPIS R., TORRELLA E., CABELLO R., et al.
- Date : 2011/08/21
- Languages : English
- Source: Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
View record
-
Replacement of HCFC-22 refrigerant with a drop-...
- Author(s) : LLOPIS R., CABELLO R., SÁNCHEZ D., et al.
- Date : 2012/02/22
- Languages : English
- Source: CYTEF 2012. VI Congreso Ibérico y IV Congreso Iberoamericano de Ciencias y Técnicas del Frío, Madrid, España, 22-24 de febrero, 2012.
- Formats : PDF
View record
-
Experimental evaluation of HCFC-22 replacement ...
- Author(s) : LLOPIS R., CABELLO R., SÁNCHEZ D., et al.
- Date : 2011/05
- Languages : English
- Source: Applied Thermal Engineering - vol. 31 - n.6-7
View record
-
Condensación de mezclas ternarias sobre tubo li...
- Author(s) : UHÍA F. J., FERNÁNDEZ-SEARA J., BASTOS S., et al.
- Date : 2012/02/22
- Languages : Spanish
- Source: CYTEF 2012. VI Congreso Ibérico y IV Congreso Iberoamericano de Ciencias y Técnicas del Frío, Madrid, España, 22-24 de febrero, 2012.
- Formats : PDF
View record
-
Fluidi refrigeranti in sostituzione all'R22.
- Author(s) : CAMPAGNA E.
- Date : 2012/07
- Languages : Italian
- Source: Industria & Formazione - vol. 36 - n. 361
- Formats : PDF