Summary
To reduce the power consumption of the cooling system in the data center effectively, a prototype of the integrated cooling unit with rotary booster and compressor was developed, and the operating characteristics were tested comprehensively according to its cooling requirements throughout the year. A data center model reflecting the characteristics of energy consumption and environmental requirements was established, the energy consumption characteristics and influencing factors of the model data center when the integrated unit was used to meet its yearly cooling requirements in the typical climate zones in China were simulated by DeST software based on the measured characteristics of the integrated cooling unit. The results showed that compared with the traditional computer room air conditioner, the energy-saving ratio of the integrated system can be as high as 39.55% for the whole year, and the energy-saving effect is remarkable. The energy-saving potential of the integrated unit becomes more significant while the heat transfer coefficient of the envelope structure becomes larger, and the load rate of IT equipment and the annually-averaged ambient temperature lower.
Available documents
Format PDF
Pages: 366-375
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Energy-saving effect of integrated cooling unit with rotary booster and compressor for data center.
- Record ID : 30027808
- Languages: English
- Subject: Technology
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 119
- Publication date: 2020/11
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2020.04.015
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (41)
See the source
-
Power-saving by air-conditioning control using ...
- Author(s) : NAKAMURA R., MARUYAMA M., TAKEUCHI A., et al.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
Experimental investigations of air conditioning...
- Author(s) : NADA S. A., ELFEKY K. E., ATTIA A. M. A.
- Date : 2016/03
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 63
- Formats : PDF
View record
-
Koeltechnologieën voor zeer energieefficiënte d...
- Author(s) : BERENDS E.
- Date : 2012/02
- Languages : Dutch
- Source: Koude & Luchtbehandeling - vol. 105
View record
-
Cooling without compressors.
- Date : 2014/12
- Languages : English
- Source: Climate Control News
View record
-
Study on outside air cooling system in data pro...
- Author(s) : KOGANEI M., YAMANAKA A., TANIOKA R., et al.
- Date : 2014/08
- Languages : Japanese
- Source: Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan - n. 209
View record