Evaluation and optimization of thermal performance and air distribution in raised-floor data center.
Number: pap. n. 311
Author(s) : LING Y. Z., ZHANG X. S.
Summary
Raised-floor data centers are the most commonly used facilities for housing computer and telecommunication equipment. The cooling of data centers and network rooms has emerged as a significant challenge as the density of computing equipment increases. The air cooling system will be inefficient when heated exhaust air re-circulation, chilled airflow by-pass and uneven air distribution occur. This paper focuses on the use of performance metrics to evaluate air distribution and thermal performance. Innovative metrics are provided. Thermal Distribution Index (TDI) is a measure of evaluating thermal distribution and cooling uniformity. It is a definition of the layer which is overcooling and undercooling. It can also tell us how many cooling capacity can be utilized. The Supply Air Index (SAI) describes whether the air distribution has achieved the cooling requirements. SAI has a good effect of evaluating the supply air temperature field and air mixing problems. These two indices could be a rule to choose proper cooling strategy. The application of these indices can help reducing energy consumption and improving equipment stability. An experimental data center has been evaluated and relevant optimization measures have been described to lower the energy consumption.
Available documents
Format PDF
Pages: 17 p.
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Evaluation and optimization of thermal performance and air distribution in raised-floor data center.
- Record ID : 30016163
- Languages: English
- Source: Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Publication date: 2015/08/16
- DOI: http://dx.doi.org/10.18462/iir.icr.2015.0311
Links
See other articles from the proceedings (657)
See the conference proceedings
Indexing
-
Best practices of energy-efficient design for a...
- Author(s) : WANG F. J., LAI C. M., HUANG Y. S., et al.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
Analysis on the large temperature difference di...
- Author(s) : ZHANG T., LIU X., JIANG J., et al.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
Comparison between conventional and local compu...
- Author(s) : TAKEUCHI J., KURABUCHI T., YOSHINO H., et al.
- Date : 2015/08/16
- Languages : English
- Source: Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
View record
-
Method for optimizing equipment cooling effecti...
- Author(s) : HERRLIN M. K., KHANKARI K.
- Date : 2008/01/19
- Languages : English
- Source: ASHRAE Transactions. 2008 Winter Meeting, New York City, NY. Volume 114, part 1 + CD-ROM.
View record
-
FLOOR DISTRIBUTION METHOD FOR SUPPLY AIR.
- Author(s) : BALANDINA L. I.
- Date : 1983/08/07
- Languages : English
- Source: [Refrigeration serving humanity]. Proceedings of the XVIth international Congress of Refrigeration.
- Formats : PDF
View record