Evaluation of HFC rotary compressor and system.

Summary

In the process of developing refrigerating systems for alternative refrigerants, two problems must be solved. First, chlorine-free refrigerants cause a decrease in lubricating ability. Second, impurities and decomposition of refrigerant oils cause capillary tube clogging. Among all types of compressors, rotary compressors face most serious problems. In the paper, the authors investigated using ether as the refrigerant oil, and a swing compressor instead of a rotary compressor. As a result, the problems were solved.

Details

  • Original title: Evaluation of HFC rotary compressor and system.
  • Record ID : 1997-1433
  • Languages: English
  • Source: Proceedings of the 1996 International Compressor Engineering Conference at Purdue.
  • Publication date: 1996/07/23