Summary
Air-source heat pumps (ASHPs) are being widely used in residential and commercial buildings and have a huge potential market and development foreground for its energy-savings, high efficiency and environmental friendliness. However, at low temperatures, frost can accumulate on the surface of the finned outdoor coil which will decrease the heating capacity and coefficient of performance (COP). This paper proposes a novel frost-free air-source heat pump water heater (ASHPWH) system, which is coupled to an extra heat exchanger coated by a solid desiccant (EHECSD) with an energy storage device (ESD). To test the system performance, experiments are carried out and the results show that the relative humidity (RH) of the air can be reduced to 52% after dehumidification and the outdoor heat exchanger can be kept frost-free for 34 min at a temperature of 0°C and relative humidity (RH) of 80%. In addition, the average COP of the system is 2.81 in a single period, which is an increase of 7.25% and 46.3% in comparison with hot-gas bypass defrosting (HGBD) and electric resistance heating (ERH) respectively. With this new technology, it has been proven that frost-free ASHPWH be achieved.
Details
- Original title: Experimental analysis on a novel frost-free air-source heat pump water heater system.
- Record ID : 30012308
- Languages: English
- Source: Applied Thermal Engineering - vol. 70 - n. 1
- Publication date: 2014/09
- DOI: http://dx.doi.org/10.1016/j.applthermaleng.2014.05.038
Links
See other articles in this issue (22)
See the source
Indexing
-
Themes:
Heat pumps techniques;
Thermal energy storage - Keywords: Hot water; Frost; Air; Energy storage; Heat pump; Performance; Desiccant
-
Experimental research on a novel frost-free air...
- Author(s) : WANG Z., WANG F., ZHENG Y.
- Date : 2015/02
- Languages : Chinese
- Source: Journal of Refrigeration - vol. 36 - n. 161
- Formats : PDF
View record
-
Study on performance evaluation of domestic hot...
- Author(s) : HAMADA Y., MURAKAWA S., NAGAHIRO S., et al.
- Date : 2009/02
- Languages : Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 143
View record
-
Development and evaluation of a building integr...
- Author(s) : BOZKAYA B., LI R., LABEODAN T., et al.
- Date : 2017/11/05
- Languages : English
- Source: Applied Thermal Engineering - vol. 126
- Formats : PDF
View record
-
Study of chemical heat pump with reaction syste...
- Author(s) : KATO Y., YAMASHITA N., YOSHIZAWA Y.
- Date : 1993
- Languages : Japanese
- Source: Kagaku Hogaku Ronbunshu - vol. 19 - n. 6
View record
-
Development of heat pump air-conditioning syste...
- Author(s) : KATSURAGI M.
- Date : 2010
- Languages : English
- Source: IEA HPC Newsl. - vol. 28 - n. 1
View record