Summary
Tube evaporators are widely used in cold storage, the single-tube two-fin tube evaporator (2-FTE) has the problems of poor heat transfer performance and low tube utilization. In this paper, a numerical simulation method is used to optimize the structure of 2-FTE, and a single-tube six-fin tube evaporator (6-FTE) structure is designed to achieve an increase in the cooling capacity per unit mass of the tube and heat transfer efficiency. Based on this, the heat transfer performance test bench of the tube evaporator is constructed, and the heat transfer performance of 2-FTE and 6-FTE is compared and tested according to the evaluation indices of cooling capacity, fin efficiency and cooling rate in the test environment from −32 °C to −6 °C. The results show that 6-FTE saves between 10.6 and 17.1% of tube consumption compared to 2-FTE for the same cooling capacity. The cooling capacity per unit tube length of 6-FTE increased by 43.9–64.7%, the cooling rate increased by 28–41%, the overall fin efficiency increased by 3.5%, and the heat transfer performance was better than that of 2-FTE, which was consistent with the simulation conclusions and in line with optimization goals. Therefore, the 6 FTE structure proposed in this paper can be an effective solution to save the manufacturing costs of refrigeration equipment for cold storage
Available documents
Format PDF
Pages: 39-52
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Experimental and numerical investigation on heat transfer performance of a single-tube six-fin tube evaporator.
- Record ID : 30032329
- Languages: English
- Subject: Technology
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 162
- Publication date: 2024/06
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2024.02.014
Links
See other articles in this issue (20)
See the source
-
The role of walk-in coolers in the cold chain.
- Author(s) : IYENGAR R. M., SRINIVASA REDDY M.
- Date : 2011/07
- Languages : English
- Source: Air Conditioning and Refrigeration Journal, Cold Chain - vol. 2 - n. 3
- Formats : PDF
View record
-
Insulation and Airtightness of Cold Rooms.
- Author(s) : IIF-IIR, DUMINIL M., IONOV A., GAZINSKI B., et al.
- Date : 2002
- Languages : English
- Formats : Hard copy
View record
-
Optimization of the thickness of thermal isolat...
- Author(s) : MIRONTCHUK Û. A., TCHEPURNENKO V. P.
- Date : 2005
- Languages : Russian
- Source: Holodil'na Tehnika i Tehnologiâ - n. 1
View record
-
Numerical modelling of finned heat exchanger.
- Author(s) : SMIERCIEW K., KOLODZIEJCZYK M., GAGAN J., et al.
- Date : 2017/09/06
- Languages : English
- Source: Compressors 2017: 9th International Conference on Compressors and Coolants.
- Formats : PDF
View record
-
Experimental investigations of heat transfer in...
- Author(s) : LAPINSKI A., BUTRYMOWICZ D.
- Date : 2021/01/13
- Languages : English
- Source: 10th IIR Conference on Compressors and Refrigerants.
- Formats : PDF
View record