Summary

High performance of absorption chiller/heater may be effectively achieved by improving the performance of absorber among heat exchangers. Differently-shaped absorber tubes such as bare tube, bumped bare tube, floral tube, twisted floral tube and a new coated tube were tested. The test results showed that the twisted floral tube and the new coated tube provide a heat and mass transfer performance 40% higher than conventional ones.

Available documents

Format PDF

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Experimental investigation of heat and mass transfer characteristics on absorber with enhancement tubes.
  • Record ID : 2000-1323
  • Languages: English
  • Source: 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
  • Publication date: 1999/09/19

Links


See other articles from the proceedings (447)