Experimental research on a new type of mixed-refrigerant fractionation refrigeration cycle in the 70 K range.

Author(s) : WANG Z. X., GONG M. Q., LIU J. Y., et al.

Summary

A new type of mixed-refrigerant fractionation refrigeration cycle was developed. The experimental system was established and mostly focused on the 70 K temperature range. The experimental results show that the cooling system can reach a temperature below 70 K and the cryocooler can provide a cooling capacity of 1 W at 72 K with a nominal input power of 500 W.

Details

  • Original title: Experimental research on a new type of mixed-refrigerant fractionation refrigeration cycle in the 70 K range.
  • Record ID : 2006-1589
  • Languages: English
  • Source: Cryogenics and refrigeration. Proceedings of ICCR 2003.
  • Publication date: 2003/04/22

Links


See other articles from the proceedings (166)
See the conference proceedings