Summary
Based on similarity theory, this research conducts a thermal-state model experiment, studying the change of circumferential in flow air on the bottom of wet cooling tower and the distribution of vortex inside tower under environmental crosswind conditions. The study on the circumferential in flow air reveals that the axisymmetric distribution of circumferential in flow air is affected by crosswind, and this phenomenon is very obvious when crosswind velocity is more than 0.2 m/s. At the velocity of 0.4 m/s, the circumferential in flow air velocity in windward side is about 1.875 times that of windless condi- tions, but the circumferential in flow air velocity in leeward side is about 0.3 times that of windless conditions. Visualization research of vortex distribution reveals that as the crosswind velocity increases, the vortex in windward side enlarges and the vortex in leeward side becomes larger at the beginning, but then gradually disappears; the vortex in leeward side reaches maximum when crosswind velocity is 0.4 m/s. The unsymmetrical circumferential in flow air and vortex under crosswind conditions seriously affect the whole air flowrate of wet cooling tower, and deteriorate the heat and mass transfer performance.
Details
- Original title: Experimental research on circumferential inflow air and vortex distribution for wet cooling tower under crosswind conditions.
- Record ID : 30010884
- Languages: English
- Source: Applied Thermal Engineering - vol. 64 - n. 1-2
- Publication date: 2014/03
- DOI: http://dx.doi.org/10.1016/j.applthermaleng.2013.12.023
Links
See other articles in this issue (19)
See the source
Indexing
-
Medida experimental del arrastre en torres de r...
- Author(s) : RUIZ J., LUCAS M., MARTÍNEZ P. J., et al.
- Date : 2012/02/22
- Languages : Spanish
- Source: CYTEF 2012. VI Congreso Ibérico y IV Congreso Iberoamericano de Ciencias y Técnicas del Frío, Madrid, España, 22-24 de febrero, 2012.
- Formats : PDF
View record
-
Le bruit des tours de refroidissement et des aé...
- Author(s) : PALENZUELA D., MOUTTE V.
- Date : 1995/04
- Languages : French
- Source: Promoclim - n. 2
View record
-
Experimental study on the performance of a mech...
- Author(s) : LUCAS M., RUIZ J., MARTÍNEZ P. J., et al.
- Date : 2013/01
- Languages : English
- Source: Applied Thermal Engineering - vol. 50 - n. 1
View record
-
Air cooled fluid coolers.
- Author(s) : SINGH J.
- Date : 2013/03
- Languages : English
- Source: Air Conditioning and Refrigeration Journal - vol. 16 - n. 2
- Formats : PDF
View record
-
Comparative experimental drift study between a ...
- Author(s) : LUCAS M., MARTÍNEZ P. J., VIEDMA A.
- Date : 2008/11
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 7
- Formats : PDF
View record