IIR document
Experimental studies on crossflow heat exchanger performance using non-azeotropic refrigerant mixture.
Author(s) : EBISU T., TORIKOSHI K.
Summary
The paper examines experimentally the performance of an air-cooled heat exchanger with two rows construction for non-azeotropic refrigerant mixture R407C. The heat exchanger performance for R407C with the present specification was the same as that for R22 under the conditions of the evaporation temperature defined by ARI Committee, but the heat exchanger performance for R407C is higher than that for R22 in the heating mode, so that the condensation temperature defined by ARI Committee is unsuitable to determine the performance of the present heat exchanger.
Available documents
Format PDF
Pages: 163-170
This document is to be digitised and will be available within 10 working days
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Experimental studies on crossflow heat exchanger performance using non-azeotropic refrigerant mixture.
- Record ID : 1996-0804
- Languages: English
- Source: For a Better Quality of Life. 19th International Congress of Refrigeration.
- Publication date: 1995/08/20
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (488)
See the conference proceedings
Indexing
-
Themes:
Heat transfer;
Blends - Keywords: R407C; Measurement; Substitute; Performance; Zeotropic mixture; Counterflow; Refrigerant; Heat exchanger
-
Characteristics of a refrigeration cycle using ...
- Author(s) : ENDOH K., MATSUSHIMA H., NONAKA M.
- Date : 1996
- Languages : Japanese
- Source: Trans. JAR - vol. 13 - n. 2
View record
-
Rilevazione continua della temperatura dell'R407C.
- Date : 2000/05
- Languages : Italian
- Source: Zero sotto Zero - vol. 9 - n. 4
View record
-
Leistungsvergleiche und Betriebserfahrungen von...
- Author(s) : HARTMANN K.
- Date : 1996/11/20
- Languages : German
- Source: DKV-Tagungsbericht 23. 1996 Leipzig.
View record
-
Study of liquid and vapour composition of refri...
- Author(s) : SUNDARESAN S. G., WATKINS R. J.
- Date : 1995/10/23
- Languages : English
- Source: Stratospheric Ozone Protection for the 90's. 1995 International CFC and Halon Alternatives Conference & Exhibition. Conference proceedings.
View record
-
Is temperature glide a good measure of dilution...
- Author(s) : GERSTEL J.
- Date : 1995/10
- Languages : German
- Source: Kälte + Klimatechnik (Die) - vol. 48 - n. 10
View record