Summary
A concept of mixing ratio of piston air is developed to evaluate the portion of the injecting air from tunnel mixed with the air in platform space of metro system. And a 3-dimensional turbulent model is used to simulate the airflow in metro platform resulted by the ventilation system and moving trains. Field measurement has been conducted to verify the 3-dimensional model. This experiment is performed during the normal operation time of a metro station with constant tracer-gas injection method. The results agree well with the numerical solution. The reason of the differences between experiment and simulation is discussed. It is concluded that the model is accurate enough for HVAC system design of metro line.
Details
- Original title: Experimental study on airflow in the underground space of a metro system with a constant tracer-gas injection technique.
- Record ID : 1999-3790
- Languages: English
- Source: CLIMA 2000, Brussels 1997, August 30 to September 2, Congress Palace.
- Publication date: 1997/08
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (45)
See the conference proceedings
Indexing
- Themes: Other air-conditioning equipment
- Keywords: China; Metro; Tunnel; Design; Underground; Air conditioning
-
Discussion on current problems and solutions of...
- Author(s) : YIN P., TAN H.
- Date : 2000/10/24
- Languages : English
- Source: International Symposium on Air Conditioning in High-Rise Buildings - 2000.
- Formats : PDF
View record
-
Current situation on development and applicatio...
- Author(s) : LANG S.
- Date : 2000/10/24
- Languages : English
- Source: International Symposium on Air Conditioning in High-Rise Buildings - 2000.
- Formats : PDF
View record
-
The first ATES project in Belgium: KBC-Bank in ...
- Author(s) : BAEL J. van, GYSEN B., VEKEMANS G.
- Date : 2001/09/15
- Languages : English
- Source: CLIMA 2000. 7th REHVA World Congress, Naples 2001 [CD-ROM + Hard-copy abstracts].
View record
-
Characteristics of the energy economy of air cu...
- Author(s) : LI Q.
- Date : 2000/07/09
- Languages : English
- Source: Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
View record
-
Potential energy savings for conditioning fresh...
- Author(s) : NIU J., ZHANG L.
- Date : 2002
- Languages : English
- Source: ASHRAE Transactions. 2002 Winter Meeting, Atlantic City, New Jersey. Volume 108, part 1 + CD-ROM.
View record