Experimental study on displacement and mixing ventilation systems for a patient ward.
Author(s) : YIN Y., XU W., GUPTA J. K., et al.
Type of article: Article
Summary
In hospital patient wards, exhalation flow from patients with airborne infectious diseases can impose health risks to caretakers and visitors. Usually, mixing ventilation is used to remove airborne contaminants, but displacement ventilation is becoming a popular alternative. This study investigated experimentally the performance of both mixing and displacement ventilation by using a full-scale environmental chamber to simulate a one-person patient ward. Results show that displacement ventilation may or may not provide a better air quality in the ward, depending on the location of the exhaust in relation to the restroom. A tracer gas (SF6) and 1 or 3 microm particles can be used to simulate contaminants breathed out by a patient. These contaminants generate similar contaminant distributions in the ward, except in the areas close to the contaminant source and the exhaust adjacent to the restroom, where the flow may be unstable. The experimental data obtained from this study can be used to validate the computational fluid dynamics (CFD) models.
Details
- Original title: Experimental study on displacement and mixing ventilation systems for a patient ward.
- Record ID : 2010-0202
- Languages: English
- Source: HVAC&R Research - vol. 15 - n. 6
- Publication date: 2009/11
Links
- External links:
See other articles in this issue (2)
See the source
Indexing
- Themes: Indoor air quality
- Keywords: Hybrid ventilation; Contamination; Ventilation; Air quality; Hospital; Expérimentation; Air conditioning
-
Mechanism of structure of indoor airflow and th...
- Author(s) : LIM E., SAGARA K., YAMANAKA T., et al.
- Date : 2008/12
- Languages : Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 141
View record
-
Prediction of vertical profile of contaminant c...
- Author(s) : SUZUKI T., SAGARA K., YAMANAKA T., et al.
- Date : 2008/11
- Languages : Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 140
View record
-
Health-care IAQ: guidance for infection control.
- Author(s) : STREIFEL A. J.
- Date : 2000/10
- Languages : English
- Source: HPAC Engineering - vol. 72 - n. 10
View record
-
Schone lucht in een gezond ziekenhuis.
- Author(s) : EIJNDE J. van den
- Date : 2008/09
- Languages : Dutch
- Source: TVVL Mag. - vol. 37 - n. 9
View record
-
Zakazenia szpitalne przenoszone droga powietrzn...
- Author(s) : KAISER K.
- Date : 2007
- Languages : Polish
- Source: Technika Chlodnicza i Klimatyzacyjna - vol. 128 - n. 10
- Formats : PDF
View record