IIR document
Generalized method for maximum heat transfer performance in two-phase closed thermosyphon.
Author(s) : GOLOBIC I., GASPERSIC B.
Summary
On the basis of comprehensive experimental results and data set available in the literature, the effects of dimensional parameters were analyzed. The generalized method for maximum heat transfer performance in a two-phase closed thermosiphon based on thermodynamical corresponding states principle was developed. The method enables the determination for fluids, where thermodynamic and transport properties are not known, needing only molecular weight, critical temperature, critical pressure and acentric factor. From the point of view of maximum heat transfer performance in two-phase closed thermosyphons, R134a is an appropriate substitute for the environmentally more harmful R12.
Available documents
Format PDF
Pages: 607-616
This document is to be digitised and will be available within 10 working days
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Generalized method for maximum heat transfer performance in two-phase closed thermosyphon.
- Record ID : 1995-2171
- Languages: English
- Source: CFCs, the Day After.
- Publication date: 1994/09/21
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (89)
See the conference proceedings
Indexing
- Themes: Heat transfer
- Keywords: R134a; Heat pipe; Calculation; Heat transfer; Thermosyphon; R12; Optimization
-
Development of an air-to-air R134a refrigerant ...
- Author(s) : DOBSON R. T., PAKKIES S. A.
- Date : 2003/01
- Languages : English
- Source: Refrig. Aircond. Afr. - vol. 18 - n. 11
View record
-
The choice of a thermostatic expansion valve fo...
- Author(s) : HEWITT N. J., MCMULLAN J. T., MORAN D. G., MURPHY N. E.
- Date : 1993/04
- Languages : English
- Source: Int. J. Energy Res. - vol. 17 - n. 3
View record
-
A simulation and design model for capillary tub...
- Author(s) : PEIXOTO R. A., BULLARD C. W.
- Date : 1994/07/19
- Languages : English
- Source: Proceedings of the 1994 International Refrigeration Conference at Purdue.
View record
-
Experimental evaluation of internal condensatio...
- Author(s) : DOBSON M. K., CHATO J. C., HINDE D. K., WANG S. P.
- Date : 1994
- Languages : English
- Source: ASHRAE Transactions 1994.
View record
-
HEAT TRANSFER BEHAVIOUR OF A RECTANGULAR THERMO...
- Author(s) : HUANG B. J., ZELAYA R.
- Date : 1988
- Languages : English
- Source: J. Heat Transf. - vol. 110 - n. 2
View record