IIR document
Improvement of the wet steam ejector performance in a refrigeration cycle via changing the ejector geometry by a novel EEC (Entropy generation, Entrainment ratio, and Coefficient of performance) method.
Author(s) : FOROOZESH F., BAK KHOSHNEVIS A., LAKZIAN E.
Type of article: Article, IJR article
Summary
In this research, the improvement of an ejector performance has been studied as crucial part of an ejector refrigeration system by means of applying changes in its geometry. Water steam is taken as a non- expensive, non-toxic, and available refrigerant and wet steam model has been employed to more accurate numerical simulation and analysis. It is investigated the effect of changing geometric parameters according to the presence of wetness in the flow field. The geometric parameters are the length and diameter of the constant area section of the ejector and the diameter of primary nozzle throat. In addition to entrainment ratio (ER) and critical compression ratio (CR) of the ejector as conventional design criteria, COP of the refrigeration system and the total entropy generation (EG) in the flow inside the ejector are also used; which results in a novel EEC ( Entropy generation, Entrainment ratio, and C oefficient of performance) method for ejector design in the ejector refrigeration systems. The impact of changing each geometry parameter is examined in a separate process. Finally, the increment in the length and diameter of the constant area section and decrement in the diameter of the primary nozzle throat are considered as desirable changes. Consequently, by applying these changes ER and COP have improved by 32% and total entropy generation is decreased.
Available documents
Format PDF
Pages: 248-261
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Improvement of the wet steam ejector performance in a refrigeration cycle via changing the ejector geometry by a novel EEC (Entropy generation, Entrainment ratio, and Coefficient of performance) method.
- Record ID : 30027305
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 110
- Publication date: 2020/02
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2019.11.006
Links
See other articles in this issue (29)
See the source
Indexing
- Themes: Ejector systems, air cycle, Stirling cycle, other cycles)
- Keywords: Geometry; Ejector system; Simulation; Performance; Entropy; COP; Water
-
Influence of ejector performance on the overall...
- Author(s) : BANASIAK K., HAFNER A.
- Date : 2013/05/09
- Languages : English
- Source: 5th Conference on Ammonia Refrigeration Technology. Proceedings: Ohrid, North Macedonia, May 9-11, 2013.
- Formats : PDF
View record
-
Simulation study for transcritical R744 refrige...
- Author(s) : KANG G. H., NA S., KIM M. S.
- Date : 2019/08/24
- Languages : English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
View record
-
Investigación en laboratorio de diferentes geom...
- Author(s) : HAFNER A., LADAM Y., ANDRESEN T., et al.
- Date : 2011/09
- Languages : Spanish
- Source: Frío Calor Aire acondicionado - vol. 39 - n. 439
- Formats : PDF
View record
-
Experimental investigation of different ejector...
- Author(s) : HAFNER A., LADAM Y., ANDRESEN T., et al.
- Date : 2010/04/12
- Languages : English
- Source: 9th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2010). Proceedings. Sydney, Australia, April 12-14, 2010.
- Formats : PDF
View record
-
Thermodynamic analysis of reversible cycles of ...
- Author(s) : PETRENKO V. A., ERIN V. A.
- Date : 2008
- Languages : Russian
- Source: Holodil'na Tehnika i Tehnologiâ - vol. 112 - n. 2
View record