IN-SITU CORROSION TEST FOR GROUND HEAT EXCHANGER MATERIALS IN SCHWALBACH GROUND COUPLED HEAT PUMP RESEARCH STATION.
Author(s) : SANNER B., KNOBLICH K.
Type of article: Article
Summary
A TEST PLANT FOR RESEARCH AND DEVELOPMENT CONCERNING GROUND COUPLED HEAT PUMPS WITH VERTICAL GROUND HEAT EXCHANGERS WAS IN OPERATION NEAR WETZLAR, GERMANY, BETWEEN 1985 AND 1989. DURING HEAT EXTRACTION TESTS BETWEEN 1986 AND 1988, 12 SAMPLES OF 5 DIFFERENT MATERIALS WERE EXPOSED TO GROUND WATER IN A 50 M DEEP WELL. IN THE ARTICLE THE MASS LOSS DUE TO CORROSION, AS WELL AS THE CHEMISTRY OF THE GROUND WATER, ARE PRESENTED. THE INVESTIGATION SHOWS THAT PURE IRON, WHEN IN CONTACT WITH GROUND WATER, WILL LOSE HALF OF ITS MASS IN APPROXIMATELY 30 YEARS. ONLY INOX STEEL OR PLASTIC (EG HIGH-DENSITY-POLYETHYLENE), ARE DURABLE ENOUGH TO JUSTIFY BEING USED AS A GROUND HEAT EXCHANGER.
Details
- Original title: IN-SITU CORROSION TEST FOR GROUND HEAT EXCHANGER MATERIALS IN SCHWALBACH GROUND COUPLED HEAT PUMP RESEARCH STATION.
- Record ID : 1992-1373
- Languages: English
- Source: IEA HPC Newsl. - vol. 9 - n. 3
- Publication date: 1991/09
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (5)
See the source
Indexing
- Themes: Heat pumps techniques
- Keywords: Germany; Copper; Ground; Heat pump; Testing; Corrosion; Heat exchanger; Underground water; Stainless steel
-
Stainless steel heat exchangers: combination of...
- Author(s) : EL'TCHINOV V., TOVARAS N.
- Date : 2005
- Languages : Russian
- Source: Holodil'nyj Biznes - n. 2
- Formats : PDF
View record
-
Stainless steel for heat-exchangers with corros...
- Author(s) : GERASIMOV V. I., HARINA I. L., KUZNECOV E. V., AKSENOVA L. I., ERSHOV N. S., VOLOSOV N. A., BUTKEVICH V. V., GREBENNIKOV V. N.
- Date : 1993
- Languages : English
- Source: Sov. J. heavy Mach. - n. 3
View record
-
Heat extraction tests with steel foundation pil...
- Author(s) : NAGANO K., KATSURA T., TAKEDA S., et al.
- Date : 2006/03
- Languages : Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 108
View record
-
SINGLE PURPOSE GROUND WATER HEAT PUMP INSTALLED...
- Author(s) : FISCHER M.
- Date : 1981
- Languages : German
- Source: Elektrowärme int., A - n. 1
View record
-
A preliminary assessment of the effects of grou...
- Author(s) : CHIASSON A. D., REES S. J., SPITLER J. D.
- Date : 2000
- Languages : English
- Source: ASHRAE Transactions. 2000 Winter Meeting, Dallas, Texas + CD-ROM.
View record