LOW CAPACITY LINDE-HAMPSON NITROGEN LIQUEFIER.

Author(s) : HEDEGARD K., ATKINS E., WALKER G.

Type of article: Article

Summary

THE AUTHORS DESCRIBE A CLOSED-CYCLE LINDE-HAMPSON NITROGEN LIQUEFIER WHICH WAS DEVELOPED IN INCORPORATING A NEW, NON-CLOGGING, DEMAND-FLOW JOULE-THOMSON NOZZLE. THE FLOW AREA OF THE NOZZLE, A TAPERED ANNULAR ORIFICE, IS REGULATED BY A VERY RUGGED LOAD-SENSITIVE DIFFERENTIAL THERMAL EXPANSION SCHEME AND BY A MANUALLY ADJUSTABLE MICROMETERMECHANISM. LABYRINTH FLOW SPOILERS WITHIN THE ORIFICE PROVIDE TURBULENT VOIDS WHICH BREAK UP AND CLEAR CONTAMINANTS FROM THE FLOW.

Details

  • Original title: LOW CAPACITY LINDE-HAMPSON NITROGEN LIQUEFIER.
  • Record ID : 1991-2382
  • Languages: English
  • Source: Adv. cryog. Eng. - vol. 35 B
  • Publication date: 1990
  • Document available for consultation in the library of the IIR headquarters only.