IIR document

Measurement of the permeability of suction filter in reciprocating compressor.

Number: pap. n. 0221

Author(s) : RUMAN R., ŠUSTEK J., TOMLEIN P.

Summary

The paper deals with permeability measurement of suction filter sample used in semi-hermetic reciprocating compressor. The main goal of the work was to verify the assumption that the suction filter made from thin stainless-steel grid can be considered as a porous medium and if it is possible to apply 1-D porous media model based on Darcy’s law and Forchheimer equation in CFD simulation for this application. For this purpose there were carried out experimental measurements of permeability of suction filter material with water. Since the materials was in the form of sheets, two measuring cells were used, one for the principal in-plane permeabilities and the other for the out-of-plane permeability. The method of permeability measurement was based on saturated parallel flow. As a result of measurements there are shown graphs with dependancies of permeability with various Reynolds number.

Available documents

Format PDF

Pages: 8

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Measurement of the permeability of suction filter in reciprocating compressor.
  • Record ID : 30022411
  • Languages: English
  • Source: Compressors 2017: 9th International Conference on Compressors and Coolants.
  • Publication date: 2017/09/06
  • DOI: http://dx.doi.org/10.18462/iir.compr.2017.0221

Links


See other articles from the proceedings (35)
See the conference proceedings