IIR document

MEASUREMENT OF THE VAPOR PRESSURE OF R13B1-SYNTHETIC OIL SOLUTIONS.

Author(s) : TAKAISHI Y., OGUCHI K.

Summary

THE VAPOR PRESSURE OF THE SOLUTIONS OF R13B1-SYNTHETIC OIL HAS BEEN MEASURED IN THE RANGE OF TEMPERATURES BETWEEN 283.15 AND 313.15 K AND PRESSURES UP TO 2.3 MEGAPASCALS. THE UNCERTAINTY OF TEMPERATURE AND PRESSURE MEASUREMENTS IS ESTIMATED TO BE 10 MILLIK AND 2 KILOPASCALS, RESPECTIVELY. THE MISCIBILITY LIMITS OBSERVED ARE ALSO REPORTED.

Available documents

Format PDF

Pages: 659-663

This document is to be digitised and will be available within 10 working days

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: MEASUREMENT OF THE VAPOR PRESSURE OF R13B1-SYNTHETIC OIL SOLUTIONS.
  • Record ID : 1992-2122
  • Languages: English
  • Source: New challenges in refrigeration. Proceedings of the XVIIIth International Congress of Refrigeration, August 10-17, 1991, Montreal, Quebec, Canada.
  • Publication date: 1991/08/10
  • Document available for consultation in the library of the IIR headquarters only.