New methods for evaluating the performance of metal hydride heat pumps.
Author(s) : SUN D. W.
Type of article: Article
Summary
Puts forward three criteria for the comprehensive assessment of a metal hydride heat pump: the actual COP, the alloy output and temperature output. States that the calculated results from these criteria, with a heat-upgrading heat pump as an example, show that the prerequisites for an improvement of system performance are lightweight reactor vessels, better metal hydrides with wide and flat plateaux and small hystereses in their P-C-T curves and measures to recover sensible heat between reactors and to enhance heat and mass transfer in the reactors. Notes the need for further research to enhance their performance.
Details
- Original title: New methods for evaluating the performance of metal hydride heat pumps.
- Record ID : 1997-0495
- Languages: English
- Source: J. Inst. Energy - n. 476
- Publication date: 1995/09
Links
See other articles in this issue (1)
See the source
Indexing
- Themes: Heat pumps techniques
- Keywords: Calculation; Metal hydride; Heat pump; Performance
-
Performance analysis of a metal-hydride heat tr...
- Author(s) : KANG B. H., YABE A.
- Date : 1996/08
- Languages : English
- Source: Applied Thermal Engineering - vol. 16 - n. 8-9
View record
-
METAL HYDRIDE HEAT PUMP.
- Author(s) : KOMAZAKI Y.
- Date : 1990
- Languages : Japanese
- Source: Refrigeration - vol. 65 - n. 754
View record
-
THE METAL HYDRIDE HEAT PUMP: DYNAMICS OF HYDROG...
- Author(s) : BJURSTROM H., SUDA S.
- Date : 1989
- Languages : English
- Source: Int. J. Hydrog. Energy - vol. 14 - n. 1
View record
-
CHARACTERISTICS OF A COMPRESSION TYPE HEAT PUMP...
- Author(s) : YONETA M., ITOH Y., WATANABE K.
- Date : 1989
- Languages : Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 39
View record
-
Compressor-driven metal-hydride heat pumps.
- Author(s) : KIM K. J., FELDMAN K. T. Jr, LLOYD G., RAZANI A.
- Date : 1997/06
- Languages : English
- Source: Applied Thermal Engineering - vol. 17 - n. 6
View record