Nitrous oxide in air separation plants.

Lachgas in Luftzerlegeranlagen./ Nitrous oxide in air separation plants.

Author(s) : WENNING U.

Type of article: Article

Summary

Nitrous oxide sometimes leads to problems in air separation plants, i.e. plugging of tubes and heat exchangers, accumulation in the rectifying column and increasing contamination of products. The paper is intended to follow the path of nitrous oxide through the plant: nitrous oxide in the atmosphere; sources of nitrous oxide; physical property data of nitrous oxide; consequences for air separation plants; molecular sieves; main heat exchanger; rectifying columns; production of rare gases.

Details

  • Original title: Lachgas in Luftzerlegeranlagen./ Nitrous oxide in air separation plants.
  • Record ID : 1999-2048
  • Languages: German
  • Source: Ber. Tech. Wiss./Rep. Sci. Technol. - n. 77/n. 60
  • Publication date: 1998/06
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (3)
See the source