Passive aircraft cooling systems for variable thermal conditions.
Author(s) : OLIVEIRA J. L. G., TECCHIO C., PAIVA K. V., et al.
Type of article: Article
Summary
A novel design for a heat exchanger system [1], for which a patent application has been filed, was experimentally evaluated in the laboratory under variable thermal conditions characteristic of an aircraft in operation. The passive heat exchanger prototype consists of a loop-thermosyphon with two condensers and a common evaporator. Water was applied as the working fluid. Natural convection, forced convection and a combination of forced and natural convection at each condenser were replicated. The fuselage condenser performance was tested at temperatures ranging from -30 to 50 °C with heat transfer coefficients ranging from natural convection to values of around 200 W/(m2 K). Air supply to the air conditioning condenser was kept at 20 °C with coefficients ranging from natural convection to around 50 W/(m2 K). Input power up to 900 W was provided to the evaporator section by an embedded electrical resistance. Cooling system malfunction is not observed when the water within the fuselage heat sink is frozen, for input power below 300 W. Under cruise flight conditions, the cooling system is able to dissipate 900 W maintaining vapor temperatures at around 41 °C. The evaporator temperature increases by approximately 0.014 °C/W when start-up occurs. Refrigeration on the ground requires air duct speeds of around 6.1 m/s to keep the vapor temperatures below 100 °C for an input power of ca. 1 kW. When forced convection acts in both condensers, the heat removal capacity of the fuselage heat sink is dominant (around 90%).
Details
- Original title: Passive aircraft cooling systems for variable thermal conditions.
- Record ID : 30015744
- Languages: English
- Source: Applied Thermal Engineering - vol. 79
- Publication date: 2015/03/25
- DOI: http://dx.doi.org/10.1016/j.applthermaleng.2015.01.021
Links
See other articles in this issue (7)
See the source
-
In-flight testing of loop thermosyphons for air...
- Author(s) : OLIVEIRA J. L. G., TECCHIO C., PAIVA K. V., et al.
- Date : 2016/04/05
- Languages : English
- Source: Applied Thermal Engineering - vol. 98
View record
-
Vapor compression system modelica library for a...
- Author(s) : ABLANQUE N., TORRAS S., OLIET C., et al.
- Date : 2018/07/09
- Languages : English
- Source: 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Heat transfer in horizontal ground heat exchang...
- Author(s) : KUPIEC K., LARWA B., GWADERA M.
- Date : 2015/01/22
- Languages : English
- Source: Applied Thermal Engineering - vol. 75
View record
-
Resení kondenzacní strany chladicích zarízení. ...
- Author(s) : PETRÁK J., PETRÁK M.
- Date : 2005
- Languages : Czech
- Source: Vytápení Vetrání Instalace - vol. 14 - n. 5
View record
-
Numerical investigation of CO2 behavior in the ...
- Author(s) : ITUNA-YUDONAGO J. F., BELMAN-FLORES J. M., ELIZALDE-BLANCAS F., et al.
- Date : 2017/03/25
- Languages : English
- Source: Applied Thermal Engineering - vol. 115
View record