Summary
The purpose of this study is to propose a new refrigeration cycle and to clarify the performance characteristics of the cycle. The authors defined a vapour compression refrigeration cycle based on the Ericsson cycle on a T-s diagram and a p-h diagram. They clarified the practical method employed of achieving isothermal compression and expansion processes through utilization of multi-stage adiabatic compressors and an ordinary expansion valve. Theoretical investigation of the cycle performance using a single stage compressor and an expansion valve demonstrated that COP values become maximum and constant when the dryness fraction is kept in a definite range. The calculation results of performance characteristics of 12 different but typical refrigerants under the conditions of -40°C evaporative temperature and 40°C condensing temperature showed distinct improvements in COP for most of the sampled refrigerants.
Available documents
Format PDF
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Performance characteristics of Ericsson's vapour compression refrigeration cycle.
- Record ID : 2009-0021
- Languages: English
- Source: 2008 Purdue Conferences. 19th International Compressor Engineering Conference at Purdue & 12th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Publication date: 2008/07/14
Links
See other articles from the proceedings (125)
See the conference proceedings
Indexing
-
Regenerative balance in magnetic Ericsson refri...
- Author(s) : DAI W.
- Date : 1992
- Languages : English
- Source: J. appl. Phys. - vol. 71 - n. 10
View record
-
The effect of field-dependent heat capacity on ...
- Author(s) : YAN Z., CHEN J.
- Date : 1992
- Languages : English
- Source: J. appl. Phys. - vol. 72 - n. 1
View record
-
Finite-time exergo-economic performance optimiz...
- Author(s) : ZHENG Z., CHEN L., SUN F.
- Date : 2007/12
- Languages : Chinese
- Source: Refrigeration - vol. 26 - n. 4
View record
-
Analysis of liquid-flooded compression using a ...
- Author(s) : BELL I., LEMORT V., BRAUN J., et al.
- Date : 2008/07/14
- Languages : English
- Source: 2008 Purdue Conferences. 19th International Compressor Engineering Conference at Purdue & 12th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Formats : PDF
View record
-
New Ericsson type cryogenic cooler.
- Author(s) : GLANS E. R.
- Date : 1994/06
- Languages : English
- Source: Cryogenics - vol. 34 - n. 6
View record