Performance evaluation and energy consumption, according to the UNI-EN 441, of commercial display cases with coolant, for medium and low temperatures.
Valutazioni prestazionali e consumi energetici secondo la norma UNI-EN 441 di Banchi Espositori Commerciali funzionanti, con fluido secondario.
Author(s) : SCHIESARO P.
Summary
In spite of their advantages, indirect cooling systems require more power than direct cooling systems. The author describes the tests he carried out on two display cases: one was a wall display case using propylene glycol-water as a coolant and operating in a temperature range of 0-8 deg C; the other was a frozen-food display case using tyfoxite water as a coolant and operating in a temperature range of -22/-24 deg C. For each series of tests, the author describes the measurement apparatus and procedures, coolant characteristics and results, with reference to the UNI-EN 441 standard. He also deals with the problems caused by the use of tyfoxite. Finally, he synthesizes the conditions of use of indirect cooling systems in commercial refrigeration.
Details
- Original title: Valutazioni prestazionali e consumi energetici secondo la norma UNI-EN 441 di Banchi Espositori Commerciali funzionanti, con fluido secondario.
- Record ID : 1998-2817
- Languages: Italian
- Source: FREE '97. Fluidi refrigeranti, espandenti, estinguenti./ FREE '97. Refrigerating, blowing and extinguishing agents.
- Publication date: 1997/04/18
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (12)
See the conference proceedings
-
Sistemas de transmisión de frío. Estado actual ...
- Author(s) : SCHWIEGEL M.
- Date : 2002/04
- Languages : Spanish
- Source: Instalador - n. 385
View record
-
Efficacité énergétique de systèmes direct et in...
- Author(s) : CLODIC D., LE PELLEC C., DARBORD I.
- Date : 1998/10/20
- Languages : French
- Source: Froid indirect en agroalimentaire. Journée française du froid : recueil des conférences.
View record
-
Application of ammonia in commercial systems: n...
- Author(s) : KRUSE H., ENKEMANN T., BURKE M.
- Date : 1996/09/27
- Languages : English
- Source: Ammonia Actualities. French and European Practical Experiences.
- Formats : PDF
View record
-
Testing of a drop-in secondary loop refrigerati...
- Author(s) : HORTON W. T., GROLL E. A., SHARP E.
- Date : 1998/06/02
- Languages : English
- Source: Natural Refrigerants, Energy Efficiency, Cost and Safety. Natural Working Fluids '98. IIR-Gustav Lorentzen Conference.
- Formats : PDF
View record
-
Dossier production du froid.
- Author(s) : VRINAT G., PAUL J., HANSEN T. M., et al.
- Date : 2003/01
- Languages : French
- Source: Rev. gén. Froid - vol. 92 - n. 1030
View record