Performance of a low-temperature ammonia-water absorption refrigeration system.

Author(s) : ROGDAKIS E. D., ANTONOPOULOS K. A.

Type of article: Article

Summary

States that absorption cooling may offer a solution to the refrigeration problem in remote locations. With conventional ammonia-water absorption units at acceptable COP, only temperatures above about minus 20 deg C are accessible. Proposes a two-stage ammonia-water absorption system for temperatures down to minus 70 deg C. Its driving force is heat (not work). Solar energy may well be used.

Details

  • Original title: Performance of a low-temperature ammonia-water absorption refrigeration system.
  • Record ID : 1993-1400
  • Languages: English
  • Subject: Developing country
  • Source: Energy, Int. J. - vol. 17 - n. 5
  • Publication date: 1992/05
  • Document available for consultation in the library of the IIR headquarters only.