Performance optimization of variable speed room air-conditioner under intermediate speed working condition.

Number: 2184

Author(s) : ZHANG L., LIU C.

Summary

Through the method of experiment and simulation, some optimized designs have been carried out to improve the performance in intermediate working conditions during the process of performance matching for APF of R32 variable speed room air-conditioner. In this paper the main reason for the poor performance in intermediate conditions of R32 air conditioning system is clarified by the analysis of the heat exchange between the refrigerant side and the air side, and some optimized designs of the indoor unit heat exchanger's pipeline layout and pipe diameter have been carried out. The optimization results show the performance of the intermediate condition has been improved by about 4%, and the performance of APF of the R32 room air conditioning system has been increased by 3.8% compared with the original unit.

Available documents

Format PDF

Pages: 10

Available

  • Public price

    20 €

  • Member price*

    15 €

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Performance optimization of variable speed room air-conditioner under intermediate speed working condition.
  • Record ID : 30028431
  • Languages: English
  • Subject: Technology
  • Source: 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
  • Publication date: 2021/05
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles from the proceedings (184)
See the conference proceedings