R450a and R513a as low-GWP substitutes of R-134a and R-507a in a medium temperature refrigeration system.
Number: pap. 1102
Author(s) : LLOPIS R., NEBOT-ANDRÉS L., CATALÁN-GIL J., et al.
Summary
This work presents the experimental evaluation of R-513A (GWP=573) and R-450A (GWP=547) as drop-in replacements of R-134a (GWP=1301) and R-507A (GWP=3987) in a commercial cabinet using a direct expansion system for medium temperature applications. The evaluation covers 24-hour energy tests using a single-stage refrigeration cycle with semihermetic compressor, electronic expansion valve and a commercial vertical cabinet with doors placed inside a climatic chamber. Tests were done at three water dissipation temperatures (23.3, 32.8 and 43.6ºC) using a constant volumetric flow rate of 1 m3·h-1. The work focuses on temperature and pressure indicators in the refrigeration system, as well as, in the energy performance using the drop-in mixture against the high-GWP refrigerants.
Available documents
Format PDF
Pages: 8
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: R450a and R513a as low-GWP substitutes of R-134a and R-507a in a medium temperature refrigeration system.
- Record ID : 30024082
- Languages: English
- Source: CYTEF 2018. IX Congreso Ibérico y VII Congreso Iberoamericano de Ciencias y Técnicas del Frío, Valencia, España, 19-21 junio 2018.
- Publication date: 2018/06/19
Links
See other articles from the proceedings (81)
See the conference proceedings
Indexing
-
Themes:
HFCs;
Supermarkets, display cabinets - Keywords: R507a; R134a; Commercial application; Display cabinet; Drop-in; R513A; R450A; Supermarket; Performance; Testing
-
Direct vs indirect commercial refrigeration at ...
- Author(s) : LLOPIS R., CATALÁN-GIL J., NEBOT-ANDRÉS L., et al.
- Date : 2018/06/19
- Languages : English
- Source: CYTEF 2018. IX Congreso Ibérico y VII Congreso Iberoamericano de Ciencias y Técnicas del Frío, Valencia, España, 19-21 junio 2018.
- Formats : PDF
View record
-
Energy evaluation of drop-in replacements for R...
- Author(s) : MAKHNATCH P., MOTA BABILONI A., KHODABANDEH R.
- Date : 2018/06/18
- Languages : English
- Source: 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
View record
-
Replacement of R-404A refrigerant in supermarkets.
- Author(s) : CALMELS O., MICHINEAU T., SUQUET T.
- Date : 2019/08/24
- Languages : English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
View record
-
Replacement of R404A at high condensation tempe...
- Author(s) : HARO ORTUNO J., MOTA BABILONI A., NAVARRO-ESBRÍ J., et al.
- Date : 2018/09
- Languages : English
- Source: 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
View record
-
Replacement of R404A at high condensation tempe...
- Author(s) : HARO ORTUNO J., MOTA BABILONI A., NAVARRO-ESBRÍ J., et al.
- Date : 2018/09
- Languages : English
- Source: 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
View record