Replacement of R404A at high condensation temperature using R454C and R455A.
Number: pap. n. 1152
Author(s) : HARO ORTUNO J., MOTA BABILONI A., NAVARRO-ESBRÍ J., et al.
Summary
R404A must be replaced for all commercial refrigeration applications following the instructions of the European F-gas Regulation. The recently developed mixtures R454C and R455A offer Global Warming Potential below 150, solutions with an ASHRAE 34 flammability classification of A2L. This paper presents and compares the experimental results of a refrigeration system using R404A, R454C and R455A, at a condensation temperature of 47 °C and evaporation temperatures of -13 and -30 °C. The experimental results show that, when using the alternative refrigerants instead of R404A, the refrigerating effect is increased, but the compressor suction density is lower. While the volumetric cooling capacity of R455A is comparable, that of R454C is lower than R404A. The coefficient of performance with both alternatives is significantly higher, so there is an energetic and hence environmental benefit from their utilization. The discharge temperature is within the limits, but it can be a limitation in higher compression ratios. The drop-in replacement only required adjustments in the TXV screw and in the refrigerant charge.
Available documents
Format PDF
Pages: 8
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Replacement of R404A at high condensation temperature using R454C and R455A.
- Record ID : 30024848
- Languages: English
- Source: 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Publication date: 2018/09
- DOI: http://dx.doi.org/10.18462/iir.hfo.2018.1152
Links
See other articles from the proceedings (126)
See the conference proceedings
Indexing
-
Themes:
HFCs;
Supermarkets, display cabinets - Keywords: R454C; Commercial application; Low GWP; Drop-in; R455A; R404A; Cooling capacity; Supermarket; Expérimentation; COP
-
Replacement of R404A at high condensation tempe...
- Author(s) : HARO ORTUNO J., MOTA BABILONI A., NAVARRO-ESBRÍ J., et al.
- Date : 2018/09
- Languages : English
- Source: 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
View record
-
Experimental evaluation of low-GWP replacements...
- Author(s) : CALLEJA-ANTA D., NEBOT-ANDRÉS L., CATALÁN-GIL J., et al.
- Date : 2019/08/24
- Languages : English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
View record
-
Examining low global warming potential hydroflu...
- Author(s) : SPLETZER S., MEDINA J., HUGHES J.
- Date : 2019/08/24
- Languages : English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
View record
-
Characteristics of R454C and R455A as R404A alt...
- Author(s) : MAKHNATCH P., MOTA BABILONI A., KHODABANDEH R., et al.
- Date : 2018/04/06
- Languages : English
- Source: 5th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Beijing, Chine, 6-8 avril 2018
- Formats : PDF
View record
-
R-454C, R-459B, R-457A and R-455A as low-GWP re...
- Author(s) : LLOPIS R., CALLEJA-ANTA D., SÁNCHEZ D., et al.
- Date : 2019/10
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 106
- Formats : PDF
View record