Reduction of energy consumption in air-conditioning systems employing direct evaporative pre-cooling of condenser air.
Number: pap. 2606
Author(s) : NDUKAIFE T. A., AGWU NNANNA A. G.
Summary
This paper presents an experimental investigation of the application of direct evaporative cooling to reduce energy consumption in a residential sized split Air-Conditioning system. Direct evaporative cooling is employed at the air-cooled condenser of a split air-conditioning system to pre-cool the ambient air flowing over the condenser coils. Different ambient conditions of air were simulated using a heater to mimic typical high temperature environments. Rigid cellulose pads with thickness ranging from 2-6 inches (5.1cm-15.24cm) served as the heat exchange medium for air-water interaction, and were tested to determine the influence of the pad thickness in pre-cooling the ambient air before it flows over the condenser coils to extract heat from the refrigerant in the condenser. It was observed that a 1°C drop in ambient air temperature causes the condensing temperature of the refrigerant to drop by 0.6°C. This drop in condensing temperature of the refrigerant causes a decrease in power consumption of the unit, accompanied by an increase in Coefficient of Performance (COP). Results obtained shows that up to 44% increase in COP, and a 20% decrease in power consumption can be achieved by employing evaporative cooling. Additionally, the COP was found to increase by 4% for every 1°C drop in refrigerant condensing temperature. The water consumption pattern of the hybrid system is monitored to provide a realistic estimate of the operating cost, and profitability of the hybrid system. It was observed that 0.34liters of water is consumed for every percent increase in COP. To provide a realistic estimate of the daily water consumption of the hybrid system, the operation time was increased from 1-4hours, in step increments of 1hour. The volume of water consumed was found to increase by a factor of 1.8, 2.5, and 3.2, for 2hrs, 3hrs and 4hrs of operation respectively. This shows that as the operating hours of the hybrid system in a day increases, the volume of water consumed will decrease.
Available documents
Format PDF
Pages: 10
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Reduction of energy consumption in air-conditioning systems employing direct evaporative pre-cooling of condenser air.
- Record ID : 30018965
- Languages: English
- Source: 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Publication date: 2016/07/11
Links
See other articles from the proceedings (274)
See the conference proceedings
-
Energetické a hlukové aspekty provozu vzduchem ...
- Author(s) : PETRÁK M.
- Date : 2009
- Languages : Czech
- Source: Vytápení Vetrání Instalace - vol. 18 - n. 2
View record
-
Experimental study of a novel shape-optimized a...
- Author(s) : KLEIN E., AUTE V., HWANG Y., LING J., MUEHLBAUER J., TANCABEL J., SHABTAY Y.
- Date : 2021/05
- Languages : English
- Source: 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Choice of the optimal construction of a regener...
- Author(s) : GARANOV S. A., PANTELEEV D. A., SOKOLIK A. N.
- Date : 2015/10
- Languages : Russian
- Source: Kholodilnaya Tekhnika - n. 10
View record
-
Heating/Cooling Fresh Air Using Hot/Cold Exhaus...
- Author(s) : KHALED M., ALI S., JABER H., FARAJ J., MURR R., LEMENAND T.
- Date : 2022/03
- Languages : English
- Source: Energies - vol. 15 - n. 5
- Formats : PDF
View record
-
Performance calculation method for refrigeratin...
- Author(s) : FEDOROV A. B., ALEJNIKOV A. E.
- Date : 1994
- Languages : Russian
- Source: Kholodilnaya Tekhnika - n. 3
View record