Retrofitting the Du Pont ternary blend into a refrigerated farm milk vat.

Author(s) : KEEDWELL R. W., BALDWIN A. J., SCOTT P. W.

Type of article: Article

Summary

Trials were conducted in which 50% of the refrigerant in the system was leaked out and the system topped up to full charge with fresh blend; three successive leaks were completed and the performance determined after each top-up. The blend composition changed somewhat with these leaks, but after the third recharge, the refrigeration capacity was only 2-3% lower than that obtained with R12.

Details

  • Original title: Retrofitting the Du Pont ternary blend into a refrigerated farm milk vat.
  • Record ID : 1994-3647
  • Languages: English
  • Source: IRHACE J. - vol. 6 - n. 2
  • Publication date: 1994/03
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (1)
See the source