IIR document
Use of hydrocarbons as drop-in replacements for HCFC-22 in on-farm milk cooling equipment.
Author(s) : CLELAND D. J., KEEDWELL R. W., ADAMS S. R.
Type of article: Article, IJR article
Summary
Many refrigeration systems on New Zealand dairy farms use HCFC-22 which is being phased out by 2015. Both laboratory and on-farm trials were undertaken to investigate hydrocarbons as drop-in replacements to HCFC-22 in milk silo refrigeration systems. A mixture of propane and ethane (Care-50) reduced energy use by 6-8%, and had similar system cooling capacity relative to HCFC-22. With propane (Care-40), energy use decreased by 5% but cooling capacity was 9% lower. The retrofits were simple and low cost because no alterations to the systems other than change in refrigerant and appropriate safety labelling and documentation were made. For most farms, the outside refrigeration system location and small charge mean that hydrocarbons could meet NZ standards for safe use of refrigerants. The low retrofit cost, improved energy efficiency, low environmental impact, mineral oil compatibility, similar cooling capacity and controllable flammability risks mean that the propane-ethane mixture is an attractive replacement for HCFC-22 on NZ dairy farms.
Available documents
Format PDF
Pages: pp. 1403-1411
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Use of hydrocarbons as drop-in replacements for HCFC-22 in on-farm milk cooling equipment.
- Record ID : 2009-2102
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 6
- Publication date: 2009/09
Links
See other articles in this issue (39)
See the source
Indexing
-
Themes:
HCFCs;
Hydrocarbons;
Milk and dairy products - Keywords: New Zealand; Milk cooler; R22; Substitute; Performance; Hydrocarbon; Energy saving; Refrigerant
-
HFC134a in farm vat dimple pads.
- Author(s) : KEEDWELL R. W., BALDWIN A. J.
- Date : 1993/11/15
- Languages : English
- Source: Cold Chain Refrigeration Equipment by Design.
- Formats : PDF
View record
-
Use of hydrocarbons as drop-in replacements for...
- Author(s) : CLELAND D. J., ADAMS S. D., KEEDWELL R. W.
- Date : 1999/09/19
- Languages : English
- Source: 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
- Formats : PDF
View record
-
Groen koudemiddel voor melkveehouderij: koolwat...
- Author(s) : NIFTERIK G. van
- Date : 1997/10
- Languages : Dutch
- Source: Koude Klim.tech. - vol. 5 - n. 10
View record
-
The dairy industry in New Zealand: new structur...
- Author(s) : MITCHELL N.
- Date : 2002
- Languages : English
- Source: Bull. FIL-IDF - n. 376
View record
-
Retrofitting the Du Pont ternary blend into a r...
- Author(s) : KEEDWELL R. W., BALDWIN A. J., SCOTT P. W.
- Date : 1994/03
- Languages : English
- Source: IRHACE J. - vol. 6 - n. 2
View record