Sustainable chilled beam design.
Author(s) : VIRTA M., ITKONEN H.
Summary
Chilled beam technology is seen as a very sustainable technology providing both excellent indoor conditions but also an energy efficient lifetime. This is a case only when different aspects of sustainability are taken into account in entire design process. It is important to optimise architectural design of building, HVAC-system design, and terminal unit selection according to indoor environmental conditions, energy use of building as well as investment and life cycle costs. This paper presents studies of a chilled beam technology in a typical office building. It takes into account the total energy consumption of HVAC-system, lighting and equipments and discusses the possibilities to reduce energy use by changing design criteria. As an example, the primary air volume (fan energy as well as heating and cooling of supply air) is one of the most important design considerations in terms of energy use. Control of lighting is the other area to pay attention. On the other hand the pumping energy is relatively small part of total energy consumption. Different selection strategies of chilled beam have also a significant influence on both room conditions and energy use.
Available documents
Format PDF
Pages: 547-557
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Sustainable chilled beam design.
- Record ID : 2009-2478
- Languages: English
- Subject: Technology
- Source: Impianti, energia e ambiente costruito: verso un benessere sostenibile. Atti 47° Congresso Internazionale AICARR: 8-9 ottobre 2009, Tivoli-Roma./ Systems, energy and built environment: toward a sustainable comfort. Proceedings 47th International Congress of AICARR: October 8-9, 2009, Tivoli-Rome.
- Publication date: 2009/10/08
Links
See other articles from the proceedings (20)
See the conference proceedings
Indexing
-
Themes:
Other air-conditioning equipment;
Comfort air conditioning - Keywords: Technology; Office; Design; Chilled beam; Case study; Air conditioning
-
Office air conditioning.
- Author(s) : LANGDON D.
- Date : 2006/02
- Languages : English
- Source: Build. Serv. J. - vol. 28 - n. 2
View record
-
Design considerations for active chilled beams.
- Author(s) : ALEXANDER D., O'ROURKE M.
- Date : 2008/09
- Languages : English
- Source: ASHRAE Journal - vol. 50 - n. 9
View record
-
La trave fredda attiva induttiva: componente ch...
- Author(s) : GUERRA N., POELMAN E., VINCI L., et al.
- Date : 2009/10/08
- Languages : Italian
- Source: Impianti, energia e ambiente costruito: verso un benessere sostenibile. Atti 47° Congresso Internazionale AICARR: 8-9 ottobre 2009, Tivoli-Roma./ Systems, energy and built environment: toward a sustainable comfort. Proceedings 47th International Congress of AICARR: October 8-9, 2009, Tivoli-Rome.
- Formats : PDF
View record
-
One cool customer.
- Date : 2006/04
- Languages : English
- Source: Build. Serv. J. - vol. 28 - n. 4
View record
-
La "poutre froide", un système de climatisation...
- Date : 1994/04
- Languages : French
- Source: Chaud Froid Plomb. - vol. 48 - n. 557
View record