Taking flexibility into account in designing beam systems.
Author(s) : KOSONEN R., VIRTA M., OY H.
Type of article: Article
Summary
In a modern office environment, balance is sought between working as individuals and the interaction between employees. It must be possible to appropriately combine various work methods, which means that partition walls and workstations should be flexibly adaptable, in order to best match the business model of each customer. The adaptability of office space is one of the central premises in designing a beam system. The systems must adapt to changed loads and partition wall locations. for a room system, adaptability means taking changes in the supply air flow, cooling effect and throw pattern of the supply air device into consideration. It must be possible to adjust the air flow supplied by the room device, which enables managing the maximum and average velocity in the occupied zone and thus reducing the risk of a draught.
Details
- Original title: Taking flexibility into account in designing beam systems.
- Record ID : 2008-2250
- Languages: English
- Source: IRHACE J. - vol. 20 - n. 3
- Publication date: 2008/05
Links
See the source
Indexing
- Themes: Comfort air conditioning
- Keywords: Office; Design; Chilled beam; Air conditioning
-
La "poutre froide", un système de climatisation...
- Date : 1994/04
- Languages : French
- Source: Chaud Froid Plomb. - vol. 48 - n. 557
View record
-
Design considerations for active chilled beams.
- Author(s) : ALEXANDER D., O'ROURKE M.
- Date : 2008/09
- Languages : English
- Source: ASHRAE Journal - vol. 50 - n. 9
View record
-
Sustainable chilled beam design.
- Author(s) : VIRTA M., ITKONEN H.
- Date : 2009/10/08
- Languages : English
- Source: Impianti, energia e ambiente costruito: verso un benessere sostenibile. Atti 47° Congresso Internazionale AICARR: 8-9 ottobre 2009, Tivoli-Roma./ Systems, energy and built environment: toward a sustainable comfort. Proceedings 47th International Congress of AICARR: October 8-9, 2009, Tivoli-Rome.
- Formats : PDF
View record
-
Première installation de climatisation avec pou...
- Author(s) : BIENFAIT D.
- Date : 1994/11
- Languages : French
- Source: Rev. gén. Froid - n. 948
View record
-
Two-pipe chilled beam system for both cooling a...
- Author(s) : AFSHARI A., NOROUZI R. G., HULTMARK G., et al.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record