The case for wide-boiling refrigerant mixtures for air conditioning.

Author(s) : HASELDEN G. G., CARTER K.

Type of article: Periodical article

Summary

The Leeds vapour compression circuit applied to air-cooled air conditioners is described in the paper. It uses vertical rifled tubes for both the evaporator and condenser, expanded into louvred fins. It uses a modulating float valve and proportional liquid injection into the compressor suction. Results are reported for air cooled from 27 to 14 deg C and 35 deg C ambient with pure R134a, progressive additions of R32, and charges of R407D and R407C.

Details

  • Original title: The case for wide-boiling refrigerant mixtures for air conditioning.
  • Record ID : 1999-1815
  • Languages: English
  • Source: Inst. Refrig., Adv. Proof - 7 p.; 1 fig.; 3 tabl.; 4 ref.
  • Publication date: 1998/11/12
  • Document available for consultation in the library of the IIR headquarters only.

Links