The use of R407C as a substitute for R22 in commercial refrigeration.
L'impiego dell'R407C in sostituzione dell'R22 nella refrigerazione commerciale.
Author(s) : LANZA W.
Summary
Summary of the technical work carried out by an Italian company on the various refrigerant mixtures available on the market, with a view to comply with environmental regulations. Comparison of two commercial refrigerating plants installed in North-Eastern Italy virtually identical, except the refrigerant. Plant A, in Arzignano, operates with R407C, plant B, in Bassano del Grappa, with R22. For both plants, the author reviews project data, plant component characteristics (evaporators, condensers, control devices, etc.), installation peculiarities and calibration parameters. He reviews the technical problems regarding plants using R407C: installation; use and replacement of dehydrant and anti-acid filters; refrigerant charging; check-up for the first weeks of operation, implementation of the liquid lines. He compares installation times and costs, and evaluates the performance in both cases (R407C and R22): operation parameters, COP. J.G.
Details
- Original title: L'impiego dell'R407C in sostituzione dell'R22 nella refrigerazione commerciale.
- Record ID : 1998-2730
- Languages: Italian
- Source: FREE '97. Fluidi refrigeranti, espandenti, estinguenti./ FREE '97. Refrigerating, blowing and extinguishing agents.
- Publication date: 1997/04/18
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (12)
See the conference proceedings
Indexing
-
Themes:
HCFCs;
Blends - Keywords: R407C; R22; Substitute; Performance; Refrigerating plant; Testing; Refrigerant
-
Systemvergleich für R22-Ersatzstoffe: R407C und...
- Author(s) : KÖNIG H.
- Date : 1998/10
- Languages : German
- Source: KI Luft Kältetech. - vol. 34 - n. 10
View record
-
Cooling performance of R407C and R410A compared...
- Author(s) : TRIEBE A. R., LINTON J. W., SNELSON W. K., et al.
- Date : 1999/09/19
- Languages : English
- Source: 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
- Formats : PDF
View record
-
Laboratory evaluation and field tests of replac...
- Author(s) : LUNDQVIST P., HERBE L.
- Date : 1996/07/23
- Languages : English
- Source: Proceedings of the 1996 Purdue International Refrigeration Conference.
View record
-
Vergleich der Kältemittel R22, R410A und R407C ...
- Author(s) : HELLMANN J., DÖRING R.
- Date : 1996/11/20
- Languages : German
- Source: DKV-Tagungsbericht 23. 1996 Leipzig.
View record
-
R407C as an alternative to R22 in vapour compre...
- Author(s) : GRECO A., MASTRULLO R., et al.
- Date : 1997/10/10
- Languages : English
- Source: Int. J. Energy Res. - vol. 21 - n. 12
View record