THERMAL ANALYSIS AND FUNDAMENTAL TESTS ON A HEAT PIPE/RECEIVER FOR A SOLAR DYNAMIC SPACE POWER SYSTEM.

Author(s) : FUJIWARA M.

Type of article: Article

Summary

ANALYSIS BY NUMERICAL SIMULATION OF THE PERFORMANCES OF A HEAT PIPE OF A SOLAR RECEIVER USED IN A CLOSED BRAYTON-CYCLE SYSTEM. COMPARISON OF THE PERFORMANCES OF A CONVENTIONAL HEAT PIPE IN WHICH THE PHASE-CHANGE EQUIPMENT IS OUTSIDE THE TUBE AND ANOTHER TUBE CONTAINS THE EQUIPMENT. A PROTOTYPE OF AN ELEMENT OF THE LATTER HEAT PIPE WAS CONSTRUCTED AND TESTED FOR DIFFERENT OPERATING CONDITIONS. (PASCAL, Bibliogr. int., ENERG., FR., N 2, 1991, 947.

Details

  • Original title: THERMAL ANALYSIS AND FUNDAMENTAL TESTS ON A HEAT PIPE/RECEIVER FOR A SOLAR DYNAMIC SPACE POWER SYSTEM.
  • Record ID : 1992-1436
  • Languages: English
  • Subject: General information
  • Source: J. sol. Energy Eng. - vol. 112 - n. 3
  • Publication date: 1990

Links