IIR document
Two-phase flow distribution in a refrigerant distributor having four indoor-unit connections of a variable refrigerant flow system.
Author(s) : HAM S., CHOI S., JEONG J. H.
Type of article: IJR article
Summary
In a variable refrigerant flow (VRF) system, the refrigerant is supplied from one outdoor unit to multiple indoor units through a header or refrigerant distributor. When the two-phase refrigerant flows into the distributor, uneven distribution occurs and deteriorate system performance. An experimental apparatus simulating the refrigerant distributor of a VRF system was constructed and air-water two-phase flow distribution characteristics were investigated. The air-water two-phase flow was more mal-distributed as the void fraction increased. A change in void fraction affected the distribution more than a change in mass flow rate in the experimental range. The flow distribution in the header was little affected by variation of the downstream flow resistance. Previous empirical correlations were investigated to predict the air-water two-phase flow distribution measured in this experiment, but performance was poor. To estimate the refrigerant two-phase flow distribution, computational fluid dynamics (CFD) simulations were performed using R410A as a working fluid. The mal-distribution of R410A appeared to be mitigated compared with air-water flow due to the large vapor phase density of R410A.
Available documents
Format PDF
Pages: 246-258
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Two-phase flow distribution in a refrigerant distributor having four indoor-unit connections of a variable refrigerant flow system.
- Record ID : 30028302
- Languages: English
- Subject: Technology
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 126
- Publication date: 2021/06
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2021.01.014
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (25)
See the source
Indexing
-
Numerical simuation of two-phase flow distribut...
- Author(s) : CHOI S., LEE H., JEONG J.
- Date : 2021/08/31
- Languages : English
- Source: 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
View record
-
Experimental and numerical investigation on a n...
- Author(s) : ZHANG C., ZHU J., LI Z., et al.
- Date : 2015/08/16
- Languages : English
- Source: Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
View record
-
Cooperative variable flow control strategy for ...
- Author(s) : JIANG X., LONG W.
- Date : 2013/06
- Languages : Chinese
- Source: HV & AC - vol. 43 - n. 278
- Formats : PDF
View record
-
Evaluation of VRF system with multi indoor unit...
- Author(s) : MATSUMOTO K., OHNO K., SAITO K.
- Date : 2015/08/16
- Languages : English
- Source: Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
View record
-
Visualization of two-phase flow through distrib...
- Author(s) : YAO Y., KUNAPULI R., HRNJAK P.
- Date : 2019/08/24
- Languages : English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
View record