A reduced GWP replacement for HFC-134a in centrifugal chillers: XP10 measured performance and projected climate impact.
Number: pap. 2487
Author(s) : KONTOMARIS K., KAUFFMAN J. P., KULANKARA S.
Summary
The performance of XP10, a new refrigerant with a reduced GWP, in a centrifugal chiller designed for HFC-134a with a cooling capacity of 1969.44 kW (560 tons) was measured under full and part load conditions and compared to performance with HFC-134a. Measured chiller energy efficiencies with XP10 were comparable to those with HFC- 134a. They resulted in 0.6% higher energy consumption for XP10 when integrated over a representative profile of partial loads as described by AHRI Standard 550/590. Based on the measured chiller performance, XP10 could be considered a near drop-in replacement for HFC-134a in centrifugal chillers. It could replace HFC-134a in existing chillers or enable optimized new chiller designs without extensive equipment and no flammability code modifications. The Total Equivalent Warming Impact (TEWI) of a chiller with XP10 was estimated under representative scenarios and compared to TEWI with HFC-134a. Use of XP10 could significantly reduce chiller global warming impact relative to HFC-134a, when chiller refrigerant losses are unavoidably high or when electricity is generated with low GHG emissions. XP10 has the potential to be a more environmentally sustainable future option for medium pressure centrifugal chillers.
Available documents
Format PDF
Pages: 10 p.
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: A reduced GWP replacement for HFC-134a in centrifugal chillers: XP10 measured performance and projected climate impact.
- Record ID : 30006647
- Languages: English
- Source: 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Publication date: 2012/07/16
Links
See other articles from the proceedings (195)
See the conference proceedings
Indexing
-
Themes:
HFCs;
Chillers;
Blends - Keywords: R134a; Measurement; Drop-in; Chiller; Substitute; Performance; GWP; Refrigerant; Centrifugal compressor; Climate
-
A reduced global warming potential replacement ...
- Author(s) : KONTOMARIS K., KULANKARA S., KAUFFMAN J. P.
- Date : 2013/10
- Languages : English
- Source: HVAC&R Research - vol. 19 - n. 7
View record
-
Use of home produced refrigerant blends for ret...
- Author(s) : SUHOMLINOV I. Â., GOLOVIN M. V., SLAVUTCKIJ D. L., et al.
- Date : 2001
- Languages : Russian
- Source: Kholodilnaya Tekhnika - n. 6
View record
-
R134a alternative refrigerant D4Yb
- Author(s) : ARIMOTO H.
- Date : 2016/04
- Languages : Japanese
- Source: Refrigeration - vol. 91 - n. 1062
View record
-
Conversion d'un centrifuge de vingt ans.
- Author(s) : TRANCART M.
- Date : 1994/07
- Languages : French
- Source: La revue pratique du froid et du conditionnement d'air - n. 799
View record
-
Low GWP chillers development.
- Author(s) : ACHAICHIA N., MATTEO G.
- Date : 2015/06/12
- Languages : English
- Source: Le ultime tecnologie del freddo e del condizionamento. Atti del 16° Convegno Europeo: June 12-13, 2015, Milano, Italia.
- Formats : PDF
View record