IIR document

Absorption heat pump using R1234ze(E) and ionic liquid for PEMFC (Proton-Exchange Membrane Fuel Cells) vehicles.

Number: pap. n. 686

Author(s) : KIM G., JUNG H. S., KIM H. J., et al.

Summary

Absorption heat pump system using R1234ze(E)/ionic fluid is developed for cooling and heating application in Proton-Exchange Membrane Fuel Cells (PEMFC) vehicles. Waste heat from the PEMFC is utilized as the heat source of the absorption heat pump system. A low global warming potential (GWP) refrigerant of (R1234ze(E)) and an ionic fluid of [hmim][Tf2N] are used as refrigerant and absorbent, respectively. Additionally, the heat pump system is assisted by a compressor placed between evaporator and absorber. Cooling and heating performance of the absorption heat pump is evaluated under various generator and absorber temperatures and concentrations. The results show that the coefficient of performance of refrigeration (COPc) is up to 0.566 and the COP of heat pump(COPH) is up to 1.517.

Available documents

Format PDF

Pages: 8

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Absorption heat pump using R1234ze(E) and ionic liquid for PEMFC (Proton-Exchange Membrane Fuel Cells) vehicles.
  • Record ID : 30026468
  • Languages: English
  • Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
  • Publication date: 2019/08/24
  • DOI: http://dx.doi.org/10.18462/iir.icr.2019.0686