Analysis of heat pump cycle using CO2/DME mixture refrigerant.

Ciclo de la bomba de calor: análisis con mezcla refrigerante CO2/DME.

Author(s) : ONAKA Y., MIYARA A., TSUBAKI K., et al.

Type of article: Article

Summary

This article is the Spanish translation of an article presented at the 12th International Refrigeration and Air Conditioning Conference, Purdue University, USA (see the Bulletin of the IIR, reference 2009-0378). In this study, the performance analysis of a heat pump cycle using carbon dioxide (CO2) and dimethyl ether (DME) non-azeotropic mixture has been carried out by cycle calculation in order to clarify the characteristics and COP of CO2/DME heat pump cycle. The calculation conditions were established as a hot-water supply system and the calculations were conducted by considering the heat transfer between the refrigerant and heat source/sink water. The heat pump cycle is formed around the critical point for high CO2 concentration mixtures and it is formed under the critical point for low CO2 concentration mixtures. The COP has the maximum at a certain pressure for each mixture and the COPs of the mixture and pure DME are higher than that of pure CO2. Operating pressure and refrigerant mass flow rate decreases with increase of DME concentration. The effects of concentration on characteristics of the cycle have also been discussed.

Available documents

Format PDF

Pages: pp. 34-40

Available

  • Public price

    20 €

  • Member price*

    15 €

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Ciclo de la bomba de calor: análisis con mezcla refrigerante CO2/DME.
  • Record ID : 2010-1297
  • Languages: Spanish
  • Source: Frío Calor Aire acondicionado - vol. 38 - n. 427
  • Publication date: 2010/07

Links


See other articles in this issue (1)
See the source