IIR document
Analysis of the performance characteristics of a refrigeration system operating on contaminated R404A refrigerant.
Number: 0766
Author(s) : GIL B.
Summary
The study conducted presents the performance of the refrigeration system operating with non-regenerated R404A and additionally contaminated with R32. Experimental studies of the refrigeration cycle have shown that a relatively small addition of R32 leads to significant changes in the system pressure analyzed. There is also a noticeable change in the compressor suction temperature, which for the averaged cycle is 6 K lower than for R404A. The reduction of the evaporating temperature and the deterioration of the heat exchange conditions lead to a reduction of the vapor superheat and, in long-term operation, to the appearance of liquid in the compressor suction line. Therefore, the advantages obtained by changing the composition of the refrigerant can only be obtained by a deliberate intervention, preceded each time by an analysis of the functioning of the cycle and the adjustment of its elements. Failure to do so may result in serious malfunction.
Available documents
Format PDF
Pages: 10
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Analysis of the performance characteristics of a refrigeration system operating on contaminated R404A refrigerant.
- Record ID : 30031876
- Languages: English
- Subject: Technology
- Source: Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Publication date: 2023/08/21
- DOI: http://dx.doi.org/10.18462/iir.icr.2023.0766
Links
See other articles from the proceedings (491)
See the conference proceedings
Indexing
-
Themes:
HFCs;
Blends - Keywords: Refrigerating system; R404A; R32; Contamination; Performance; Mixture; Compressor; Energy efficiency; Nucleate boiling; Expérimentation
-
Nucleate boiling heat transfer coefficients of ...
- Author(s) : JUNG D., SONG K., AHN K., et al.
- Date : 2003/11
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 26 - n. 7
- Formats : PDF
View record
-
Mezclas HFC/HFO para sustituir al R404A en refr...
- Author(s) : MOTA BABILONI A., BARRAGÁN-CERVERA A., NAVARRO-ESBRÍ J., et al.
- Date : 2016/05/03
- Languages : Spanish
- Source: CYTEF 2016. VIII Congreso Ibérico y VI Congreso Iberoamericano de las Ciencias y Técnicas del Frío, Coimbra-Portugal, 3-6 mayo, 2016.
- Formats : PDF
View record
-
Wrzenie czynnika chlodniczego w warunkach zabur...
- Author(s) : BOHDAL T.
- Date : 2005
- Languages : Polish
- Source: Chlodnictwo - vol. 40 - n. 9
View record
-
Nucleate pool boiling heat transfer coefficient...
- Author(s) : SUN Z., GONG M., LI Z., et al.
- Date : 2007/01
- Languages : English
- Source: International Journal of Heat and Mass Transfer - vol. 50 - n. 1-2
View record
-
Experimental investigation of local nucleate bo...
- Author(s) : FUKUJU R., ENOKI K., SAITO K.
- Date : 2021/08/31
- Languages : English
- Source: 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
View record