IIR document
Basic performance of CO2 cyclone refrigeration system.
Number: 1199
Author(s) : WAKIMOTO H., UCHI K., YAMASAKI H., YAMAGUCHI H., KAMIMURA T., HATTORI K., NEKSÅ P.
Summary
The CO2 refrigeration system is unique in a way that the sublimation heat of dry-ice made at the expansion process is utilized by a newly designed cyclone separator-evaporator in the low-pressure cycle side of a cascade heat pump cycle. In the present study, the effectiveness of the cyclone separator-evaporator is examined and the basic performance of the system is evaluated by measuring temperature and pressure obtained by the cyclone separator-evaporator. The system performance is at the same time verified by adopting the exergy analysis of the system. The results of the present study show a promising outcome from the experimental system, such that avoidance of dry-ice blockage in the conventional evaporator is possible in the temperature range below -56.6˚C.
Available documents
Basic Performance of CO2 Cyclone Refrigeration System
Pages: 6
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Basic performance of CO2 cyclone refrigeration system.
- Record ID : 30027920
- Languages: English
- Subject: Technology
- Source: 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2020). Proceedings. Kyoto, Japon, December 7-9th 2020.
- Publication date: 2020/12/07
- DOI: http://dx.doi.org/10.18462/iir.gl.2020.1199
Links
See other articles from the proceedings (120)
See the conference proceedings
Indexing
-
Themes:
CO2;
Heat pumps techniques - Keywords: CO2; Low temperature; Cascade system; Dry ice; Sublimation; Evaporator; Expérimentation; Exergy
-
Experimental study on system performance of ult...
- Author(s) : IWAMOTO Y., YAMASAKI H., NIU X. D., et al.
- Date : 2015/08/16
- Languages : English
- Source: Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
View record
-
Low temperature subcritical refrigeration cycle...
- Author(s) : SOBIERAJ M.
- Date : 2022/06/13
- Languages : English
- Source: 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Formats : PDF
View record
-
Ultra-low temperature refrigeration system of C...
- Author(s) : YAMAGUCHI H., ISHIKAWA Y., YAMASAKI H., KAMIMURA T., HATTORI K., NEKSA P.
- Date : 2022/06/13
- Languages : English
- Source: 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Formats : PDF
View record
-
Carbon dioxide as a possible low temperature re...
- Author(s) : GERMANUS J., RÖLLIG P.
- Date : 2017/05/11
- Languages : English
- Source: 7th Conference on Ammonia and CO2 Refrigeration Technology. Proceedings: Ohrid, North Macedonia, May 11-13, 2017.
- Formats : PDF
View record
-
Heat pump operating with NH3 or CO2 - A compara...
- Author(s) : DOBROVICESCU A., SERBAN A., FILIPOIU C., et al.
- Date : 2015/08/16
- Languages : English
- Source: Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
View record