Summary
Air curtain is efficient to confine a certain space in the traditional application. In this paper, air curtain is utilized to create a local indoor environment. The energy saving potential is numerically investigated by a typical room. The indices such as air curtain effectiveness and curtain COP are adopted to evaluate the performance in different heat source characteristics conditions. The influence of heat proportion, total heat amount, working station amount and wall conditions are taken into consideration. The results show that air curtain has the ability to create a non-uniform indoor environment, and the maximum temperature difference on the two sides of air curtain can be maintained 7.4°C. Air curtain is especially useful if the heat source is mainly concentrated in the unoccupied space, but is useless if the whole room is occupied or the heat is mainly in the occupied zone.
Available documents
Format PDF
Pages: 8 p.
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Can air curtains be used to build a non-uniform indoor environment and save energy?
- Record ID : 30015942
- Languages: English
- Source: Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Publication date: 2015/08/16
- DOI: http://dx.doi.org/10.18462/iir.icr.2015.0236
Links
See other articles from the proceedings (657)
See the conference proceedings
Indexing
- Themes: Other air-conditioning applications
- Keywords: Heat; Air curtain; Simulation; Performance; Energy saving; Air conditioning; Distribution
-
Energy savings using air curtains installed in ...
- Author(s) : LAWTON E. B., HOWELL R. H.
- Date : 1995/06/24
- Languages : English
- Source: ASHRAE Transactions.
View record
-
SCALE MODEL EXPERIMENTS ON COOLING AND HEATING ...
- Author(s) : SHODA T., TSUCHIYA T.
- Date : 1981
- Languages : Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 16
View record
-
Die unsichtbare Luftbarriere: Luftschleier für ...
- Author(s) : FUSS G.
- Date : 2011
- Languages : German
- Source: Technik hoch zwei - n. 1
- Formats : PDF
View record
-
SECOND GENERATION AIR CURTAIN.
- Author(s) : WALDRON P.
- Date : 1990/10
- Languages : English
- Source: H&V Eng. - vol. 63 - n. 703
View record
-
The performance of a gas-engine-driven heat pum...
- Author(s) : SCHIBUOLA L.
- Date : 1993/08
- Languages : Italian
- Source: Cond. Aria - vol. 37 - n. 8
View record