COOLING OF THE < POULTRY AND GAME > AREA AT THE PARIS-RUNGIS INTERNATIONAL MARKET.

MISE SOUS FROID DU PAVILLON < VOLAILLES ET GIBIERS > AU MARCHE INTERNATIONAL PARIS-RUNGIS.

Author(s) : GAUTHIER J. L., VELIN P.

Type of article: Article

Summary

REFRIGERATING EQUIPMENT DESIGNED FOR MAINTAINING DIFFERENT SECTIONS OF THE MARKET AT AN AMBIENT TEMPERATURE NOT GREATER THAN 280 K (7 DEG C), WITHOUT PARTICULAR CONTROL OF RELATIVE HUMIDITY IS DESCRIBED. THE EQUIPMENT INCLUDES: A CENTRAL REFRIGERATING UNIT (2,000 KILOWATTS OF REFRIGERATION IN 4 GLYCOL-WATER COOLERS OF 500 KILOWATTS (INCLUDING A TOTAL OF 32 COMPRESSOR UNITS) ; (AIR-COOLED) CONDENSERS ; THE DISTRIBUTION SYSTEM FOR GLYCOL WATER AND AIR COOLERS. THE MONITORING, CONTROL, AUTOMATION AND REGULATION SYSTEMS ARE DETAILED, AS WELL AS THE METHOD OF AND EQUIPMENT FOR THE < DECENTRALIZED TECHNICAL MANAGEMENT > SYSTEM. THE MODERNIZATION OF THE SALES MARKET BY IMPLEMENTING A COOLING SYSTEM IS DISCUSSED, TOGETHER WITH A DESCRIPTION OF THE INITIAL CONSTRUCTION WITHOUT THIS COOLING SYSTEM. THE IMPROVED RESULTS DURING THE HOT SUMMERS OF 1989 AND 1990, FOLLOWING RETROFITTING, ARE MENTIONED. J.R.

Details

  • Original title: MISE SOUS FROID DU PAVILLON < VOLAILLES ET GIBIERS > AU MARCHE INTERNATIONAL PARIS-RUNGIS.
  • Record ID : 1991-1670
  • Languages: French
  • Source: Rev. gén. Froid - vol. 80 - n. 10
  • Publication date: 1990
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (2)
See the source