Summary

The current cooling rate and weight loss were measured in 14 beef chillers in commercial use. Beef sides were unloaded from the chiller between 24 and 48 h after loading but a deep leg temperature of 7 °C or less on unloading was achieved in only 4 of the chillers. The weight losses were between 1.1 and 2% after 24 hours and between 1.5 and 2.3% after 48 hours and this value represented 20 times the cost of the energy used.