IIR document
Determination of capacity for expansion valve for different refrigerants.
Author(s) : RATHJE P., ZANGENBERG J.
Summary
Expansion valves have been manufactured through more than 60 years, but there is still a lot of problems that need further clarification. If the valve can be described with good accuracy by a one-nozzle model, then the conversion calculation from one refrigerant to another can be done with satisfactory accuracy. If the current condition deviates considerably from the standard test condition or the valve has a considerable pressure drop in the housing, then it will be better to use a multi-nozzle model or another more sophisticated method.
Available documents
Format PDF
Pages: 728-735
This document is to be digitised and will be available within 10 working days
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Determination of capacity for expansion valve for different refrigerants.
- Record ID : 1996-0877
- Languages: English
- Source: For a Better Quality of Life. 19th International Congress of Refrigeration.
- Publication date: 1995/08/20
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (488)
See the conference proceedings
Indexing
-
Adiabatic capillary tube expansion devices work...
- Author(s) : ESCANES F., PÉREZ-SEGARRA C. D., OLIVA A.
- Date : 1994/07/19
- Languages : English
- Source: Proceedings of the 1994 International Refrigeration Conference at Purdue.
- Formats : PDF
View record
-
Experimental analysis of capillary tubes for CF...
- Author(s) : MELO C., FERREIRA R. T. S., BOABAID-NETO C., GONCALVES J. M., THIESSEN M. R.
- Date : 1994/07/19
- Languages : English
- Source: Proceedings of the 1994 International Refrigeration Conference at Purdue.
View record
-
A simulation and design model for capillary tub...
- Author(s) : PEIXOTO R. A., BULLARD C. W.
- Date : 1994/07/19
- Languages : English
- Source: Proceedings of the 1994 International Refrigeration Conference at Purdue.
View record
-
The behaviour of lateral and concentric capilla...
- Author(s) : PAIVA M. A., VODIANITSKAIA P., NETO A. H., MATTOS-SILVARES O. de, FIORELLI F.
- Date : 1994/07/19
- Languages : English
- Source: Proceedings of the 1994 International Refrigeration Conference at Purdue.
View record
-
Stabilité de fonctionnement d'un détendeur ther...
- Author(s) : TAMAINOT Z., OUTTAGARTS A., HABERSCHILL P., LALLEMAND M.
- Date : 1993/11/01
- Languages : French
View record