DEVELOPMENT OF HIGH-TEMPERATURE HEAT PUMP USING ALTERNATIVE MIXTURES.

Author(s) : NAKATANI K.

Summary

4 KINDS OF MIXTURES R22-R134A, R22-R152A, R22-R142B AND R22-R123, WERE EVALUATED IN ORDER TO REALIZE HIGHER CONDENSING TEMPERATURE THAN THAT USING R22 AT HIGH TEMPERATURE OPERATION, AND LARGER HEATING CAPACITY THAN THAT USING R22-R114 AT NORMAL TEMPERATURE OPERATION. THESE MIXTURES WERE APPLIED TO A NEWLY-DEVELOPED COMPOSITION CHANGEABLE RECTIFYING CIRCUIT IN WHICH THE HIGHER-BOILING-POINT REFRIGERANT WASSPRDO. THE COMPOSITION CHANGEABLE HIGH-TEMPERATURE HEAT PUMP INDICATED THE MOST EFFECTIVE CHARACTERISTICS WHEN USING R22-R142B AS THE REFRIGERANT.

Details

  • Original title: DEVELOPMENT OF HIGH-TEMPERATURE HEAT PUMP USING ALTERNATIVE MIXTURES.
  • Record ID : 1991-1352
  • Languages: English
  • Publication date: 1990/07/17
  • Source: Source: USNC-IIR/Proc. 1990 Refrig. Conf., Purdue Univ./ASHRAE, Purdue CFC Conf./Purdue Univ., Ray W. Herrick Lab., Sch. mech. Eng.
    459-465; 4 fig.; 6 tabl.; 3 ref.
  • Document available for consultation in the library of the IIR headquarters only.