Energy efficiency of a household air conditioner using new HFC refrigerants.

Summary

An advanced simulation model of a household air conditioner, split system, was developed. The compressor was characterised by its isentropic efficiency and the finned coils, condenser and evaporator, were modelled by an elementary finite volume technique. The aim of the paper is comparing the performance of R22 with that of some possible HFC substitutes (R407C, R134a, R32, R410A, R404A). In general, refrigerants with high amount of exergy losses during throttling take greater advantage from this practice. At last, some considerations are proposed on the different behaviour of the refrigerants with respect to the isentropic efficiency of the compression and the related COP of the cycle.

Available documents

Format PDF

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Energy efficiency of a household air conditioner using new HFC refrigerants.
  • Record ID : 2004-1046
  • Languages: English
  • Source: 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
  • Publication date: 2003/08/17

Links


See other articles from the proceedings (398)