Summary
The energy consumption of a refrigerator with R152a is about 10% lower than that with R12, and that with R12 is basically the same as that with R152a-R22. The results also show that the freezing level of the mixture R152a-R22-R114 is basically the same as that of R12, the energy consumption of R152a-R22-R114 is approximately 3% lower than that of R12.
Details
- Original title: Experimental research with the replacing fluids in the household refrigerator.
- Record ID : 1993-0793
- Languages: English
- Publication date: 1992/07/14
- Source: Source: Proc. 1992 int. Compress. Eng. Conf., Purdue Univ.
vol. 3; 1003-1008; 3 fig.; 4 tabl.; 1 ref. - Document available for consultation in the library of the IIR headquarters only.
Indexing
-
Themes:
CFCs;
HCFCs;
HFCs;
Blends;
Domestic applications (refrigerators, freezers) - Keywords: R114; Household refrigerator; R22; R152a; R12; Performance; Mixture; Refrigerant
-
An investigation on the performance of refriger...
- Author(s) : XIE G., DANG K., WU Y., et al.
- Date : 1992/07/14
- Languages : English
View record
-
Compressor performance tests of HFC152a and HFC...
- Author(s) : LIU Z., et al.
- Date : 1992
- Languages : Chinese
- Source: Journal of Refrigeration - n. 1
View record
-
Development of a high-efficiency domestic refri...
- Author(s) : WU Y., XIE G., LI X. Z.
- Date : 1994/03
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 17 - n. 3
- Formats : PDF
View record
-
The experimental study on refrigerant mixture a...
- Author(s) : HUA X. L., CHEN W., YIN G. W.
- Date : 1992/07/14
- Languages : English
View record
-
AN INVESTIGATION ON THE APPLICATION OF REFRIGER...
- Author(s) : XIE G. Z., et al.
- Date : 1991/08/10
- Languages : English
- Source: New challenges in refrigeration. Proceedings of the XVIIIth International Congress of Refrigeration, August 10-17, 1991, Montreal, Quebec, Canada.
- Formats : PDF
View record