Energy efficiency of HFC134a versus HFC152a.
Author(s) : VINEYARD E. A., SWATKOWSKI L. J. Jr
Summary
In an effort to evaluate the tradeoff between efficiency and safety of two alternative refrigerants, R152a (flammable), and R134a (non-flammable), energy consumption tests were performed by six refrigerator-freezer manufacturers as part of a joint project. The results showed no statistically significant difference between the efficiencies of R134a and R152a. Thus, R134a is a more acceptable substitute for R12 in refrigerator-freezers than R152a assuming safety is the main criterion.
Details
- Original title: Energy efficiency of HFC134a versus HFC152a.
- Record ID : 1994-2279
- Languages: English
- Source: The 1993 International CFC and Halon Alternatives Conference. Stratospheric Ozone Protection for the 90's. Proceedings.
- Publication date: 1993/10/20
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (47)
See the conference proceedings
Indexing
-
EFFECTS OF AMBIENT TEMPERATURE AND CONTROL SETT...
- Author(s) : FARLEY K. J.
- Date : 1987
- Languages : English
View record
-
R152a versus R134a in domestic refrigerator-fre...
- Author(s) : SANVORDENKER K. S.
- Date : 1992/07/14
- Languages : English
View record
-
Evaluation of R134a and R152a as working fluids...
- Author(s) : PANNOCK J., LIU Z., RADERMACHER R., YU K.
- Date : 1994
- Languages : English
- Source: ASHRAE Transactions 1994.
View record
-
DESIGN AND CONSTRUCTION OF AN EFFICIENT US-TYPE...
- Author(s) : PEDERSEN P. H.
- Date : 1987/08/24
- Languages : English
- Source: Development in refrigeration, refrigeration for development. Proceedings of the XVIIth international Congress of Refrigeration.
- Formats : PDF
View record
-
Verification of refrigerated appliance rated en...
- Author(s) : SLUIS S. M. van der
- Date : 1999/09/19
- Languages : English
- Source: 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
- Formats : PDF
View record